Permit Number: T09OT00017
Parcel: 11810134D

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T09OT00017
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2009 BIANCA RAMIREZ ENGINEERING REVIEW Approved January 9, 2009
FLOODPLAIN USE PERMIT # T09OT00017
PROJECT ADDRESS: 2424 S Cottonwood Lane #132
APPLICANT'S NAME: Sheila Millette
PROPERTY OWNER: Doug Page


This parcel lies in a FEMA AE Zone map number 040076 C 2228K, effective date February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

2424 S Cottonwood Lane #132, Tucson, AZ 85713, COTTONWOOD PARK LOT 114 EXC THAT PTN LYG N LINE 11421.11 S SILVERLAKE RD EXC THAT PTN LYG SW CENTERLINE OF DRGWY. In a portion of Township 14 South, Range 13 East, Section 23, for the set-up of a replacement manufactured home.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) The proposed manufactured home set-up is located within an existing manufactured home park, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance), and is exempt from the requirement of placing the manufactured home replacement on a permanent foundation.

4) For purposes of this permit the following flood elevations shall be used:
Base Flood Elevation (BFE) = 2382.0 feet NGVD 1929
Regulatory Flood Elevation (RFE) = 2383.0 feet NGVD 1929
Bottom of the structural frame of the manufactured home and lowest point of any attached appliances to be at or above the Regulatory Flood Elevation (RFE).

5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to manufactured home electrical inspection or habitation. The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the manufactured home as well as the identity and location of all other equipment/machinery servicing the manufactured home.

6) Certification by an Arizona State Registered Professional Civil Engineer that the installation of the manufactured home meets all the requirements of Section 26-9 of the Ordinance is required.

7) The manufactured home must be securely anchored and installed with tie downs per State of Arizona requirements.

8) All work shall conform to the approved details and general site plan, which are made part of this permit.

9) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T09OT00017 FOR INFORMATION PLEASE CALL 791-5550."

10) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.

11) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

12) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the installation of the replacement manufactured home.

13) See the associated activity T08MH00136.

This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 1 Day: 9 Year: 2010

APPLICANT/CONTRACTOR: Sheila Millette
ADDRESS: 4275 N Plum, Tucson, Arizona 85705
PHONE: (520) 888-2965
OWNER: NHC-AZ101 LLC (Doug Page)
ADDRESS: 2424 S Cottonwood Lane #132, Tucson, Arizona 85251
PHONE:


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/17/2009 SUE REEVES APPROVAL SHELF Completed
02/17/2009 DELMA ROBEY OUT TO CUSTOMER Completed