Permit Number: T09MH00021
Parcel: 137276370

Address:
2051 W DREXEL RD

Review Status: Completed

Review Details: MOBILE HOME

Permit Number - T09MH00021
Review Name: MOBILE HOME
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/01/2009 STEVE SHIELDS ZONING REVIEW Approved
05/19/2009 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Approved
05/19/2009 LMAKUS1 NPPO REVIEW Passed
05/19/2009 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Approved WEST DISTRICT, 2112 SQ FT, IMPACT FEES: $8070.12
05/19/2009 GERRY KOZIOL WWM REVIEW Approved
05/19/2009 LOREN MAKUS ENGINEERING REVIEW Approved May 19, 2009 (Special Inspection Required)

The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:
2051 West Drexel Road for the purpose of installing a Manufactured Home in a AO-1 flood hazard area (FEMA Panel 2220) along with associated site development.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit.

1. All work shall conform to the improvement plans submitted as Activity T09MH00021 and Grading Permit T09BU00725 which is made part of this permit.

2. The lowest structural member and all associated facilities of the buildings in the property under this permit shall be placed a minimum of 2453.2 feet above mean sea level, NGVD 1929 as Certified by a Registered Land Surveyor. The adjacent natural grade has been determined to be 2551.2 feet above mean sea level NGVD 1929. This certification must be completed and returned to the Development Services Department, Engineering Section on the first floor of the County/City Public Works Building at 201 N. Stone Avenue.

3. The existing drainage patterns at the property lines shall not be obstructed except as approved by the grading plan.

4. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

5. This permit becomes invalid and is subject to additional floodplain review, if any required development permit(s') changes the configuration of the structure and or site development.

6. This permit does not authorize the construction of any perimeter walls. Any walls or other structures on this parcel will require a separate Floodplain Use Permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit.

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.