Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T09CM03408
Parcel: 13409018B

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T09CM03408
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/27/2010 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens

PROJECT: T09CM03408
8575 E. Broadway Blvd
Site Plan

TRANSMITTAL DATE: 02/02/10

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1. DS 2-02.2.1.A.5 A search of the Pima County Assessors records indicates this property is shown as a separate parcel (134-09-018b). The design as shown appears to have the building located over the property line. A tax parcel combination will be required to be completed and a covenant regarding development and use of real property completed and recorded prior to approval of this site plan. Provide recording docket and page information for the covenant on the site plan. Provide appropriate documentation with next submittal

2. A lease area is indicated on the site plan. Approval of the lease area must be obtained by submitting through PDSD for a lot split. Completion and approval of the lot split must be obtained prior to approval of the site plan. Provide appropriate documentation with next submittal

3. Provide lot line distances and bearings for all property lines.

4. Remove the "90%" from the parking calculations.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\T09CM03408-2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents

Final Status

Task End Date Reviewer's Name Type of Review Description
05/13/2010 DELMA ROBEY OUT TO CUSTOMER Completed
05/13/2010 SUE REEVES REJECT SHELF Completed