Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM03332
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/08/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
01/26/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 1-26-10 Activity: T09CM03332 Address: 534 S Longfellow Ave Applicant: Jesus Maldonado Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. General note number 1 on sheet number 3 is inconsistent with other plan pages. PLUMBING PLAN: 3. Provide an accurate fixture unit schedule for the water supply system (2 lavatories in new bath; clothes washer = 4 f.u.; bathtub = 4 f.u.) and verify sufficient pipe sizing, UPC Tables 6-5. MECHANICAL PLAN: 4. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. ELECTRICAL PLAN: 5. Circuit number 22 requires arc-fault protection, E3802.12. 6. Show the location of the proposed service panel on the electrical plan, E3305.2, E3501.6.2. 7. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. All plan pages should reference this code. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/28/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |