Permit Number: T09CM03331
Parcel: 12311234A

Address:
1240 E SENECA ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU

Permit Number - T09CM03331
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2010 STEVE SHIELDS ZONING REVIEW Approved
01/07/2010 JASON GREEN ENGINEERING REVIEW Approved January 7, 2010
FLOODPLAIN USE PERMIT NO.: T10OT00041
ADDRESS: 1240 E Seneca St, Tucson Arizona 85719
PROPERTY OWNER: James Callegary
1240 E Seneca St, Tucson AZ 85719

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Mountain Ave Wash delineation, specifically described as:

A portion of Parcel 123-11-234A, Monterey Amended Lot 3 & E30' of Lot 2 BLK 21

For the purpose of an addition, front porch and remodeling of an existing non-conforming single-family residence.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following 13 conditions:
1) All improvements proposed under this permit will be cumulative in percentage, to include this project.
2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value.
3) A cost estimate was provided showing that the improvements are less than 50 % (estimate was 27.4%) of the assessed value ($84,832), as shown on the Pima County Assessors Website. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and if piecemeal permits for this construction are applied for the cost estimate will be added to it.
4) All work shall conform to the approved Details and General site plan sheets which are made part of this permit.
5) This project is located in a City of Tucson Flood Hazard Area per the City of Tucson Mapguide Floodplain delineation of Mountain Ave Wash.
6) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
7) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times.
8) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval.
9) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance.
10) The associated improvements are with permit activity number T09CM03331
11) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
12) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.
13) This permit is specific to the improvements for 1240 E Seneca St as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Vance Goodman
ADDRESS: 1620 N Wilmot Road, Tucson AZ 85712
PHONE: 520-245-1214
OWNER: James Callegary
ADDRESS: 1240 E Seneca St, Tucson AZ 85719
PHONE: 520-791-7430

(EXPIRATION DATE) Month: _01 Day: 07 Year: 2011

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
01/07/2010 SSHIELD1 NPPO REVIEW Passed
01/07/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Approved