Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM03230
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/25/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 1-26-10 Activity: T09CM03230 Address: 4155 E Kilmer St Applicant: David Woodruff Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FLOOR PLAN: 2. Specify use of existing rooms adjoining the proposed addition. Note: removing existing windows from sleeping rooms may require a new emergency escape rescue opening, R310. FOUNDATION PLAN: 3. a Specify and locate all foundation hold-downs (at end studs) for alternate brace wall panels, R602.10.6. STRUCTURAL / FRAMING PLAN: 4. Justify the proposed double 2x12 ridge beam for the intended span, R801.2. 5. Specify the framing member size for the hip rafters at the rear porch, R801.2. SECTIONS - DETAILS: 6. Specify a manufacturer of the asphalt shingles that will uphold a warrantee for an unvented attic assembly. PLUMBING PLAN: 7. Provide a sleeve for the existing gas line or relocate out from underneath the proposed structure, UPC 1211.1.6. 8. Specify the size of the existing sewer to be tapped and the number of water closets in the existing building, UPC Table7-5 footnote 4. 9. Specify the size of the existing water supply line to the building and the size of the existing water meter, UPC Table 6-6. OUTDOOR LIGHTING CODE 10. The maximum unshielded limit for this property is 4,080 lumens (12,000 * 0.34) show compliance for new outdoor lighting fixtures, OLC 3.1.2. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 12/31/2009 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/28/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |