Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM03204
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/11/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | December 11, 2009 FLOODPLAIN USE PERMIT # T09OT02663 PROJECT ADDRESS: 1102 S Duke Drive APPLICANT'S NAME: Metro Permit Express PROPERTY OWNER: Mary Catherine O'Connell This parcel lies in a FEMA X (100-year floodplain) Zone map number 040076 C 2253K, effective date February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA. The proposed development is also located within a FEMA X (100-year floodplain). The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: 134-24-1810; 1102 S Duke Drive, Tucson, AZ 85710, YALE ESTATES LOT 15 BLK 14. In a portion of Township 14 South, Range 15 East, Section 18, for the addition of a Bathroom and Laundry Room to an existing non conforming structure. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions apply to this permit: 1) If improvements equal or exceed 50% of the current value of the structure; no other improvements will be permitted unless the entire structure is brought into compliance with the City of Tucson Floodplain and Erosion Hazard Area Regulations (Chapter 26, Tucson Code). If the project is determined to be a substantial improvement, and, if it is determined that the lowest flood elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for floodproofing will be required and shall conform to current City of Tucson and FEMA floodplain development requirements in effect on the date of authorization by the Development Services Department. 2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value. 3) Per the cost estimate provided by Planning and Development Services - Residential Department of ($16,923.70) was provided showing that the improvements are less than 50 % (estimate was less than 21%) of the assessed value of the structure per the 2006 Pima County Assessor Property Inquiry excluding land value - $80,446.00). No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and any future improvements will be added to it. 4) This project is located in a FEMA special identified flood hazard area, Zone X (100-year). 5) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 6) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times. 7) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval. 8) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance. 9) The associated improvements are with permit activity number T09CM03204. 10) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents. 11) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. 12) This permit is specific to the improvements for 1102 S Duke Drive, as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Metro Permit Express ADDRESS: 3619 E Speedway Blvd #101, Tucson, AZ 85716 PHONE: 602-990-6866 OWNER: Mary Catherine O'Connell ADDRESS: 1102 S Duke Dr, Tucson, AZ 85712 PHONE: (EXPIRATION DATE) Month: 12 Day: 11 Year: 2010 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 12/14/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/22/2009 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 12-30-09 Activity: T09CM03204 Address: 1102 S Duke Dr Applicant: Metro Permit Express Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Verify construction type specified consistent with the 2006 IBC or remove note for IRC design. STRUCTURAL PLANS: 3. Specify roof framing members (size, spacing and span) for verification of structural integrity of new dead loading, R801.2. SECTIONS - DETAILS: 4. Vented frieze boards should only be utilized for ventilated attic spaces. 5. Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. PLUMBING PLAN: 6. Specify water conservation requirements: Water closets = 1.6 gallons per flush, Sinks = 2.2 gpm, Showerheads = 2.5 gpm, P2903.2. ELECTRICAL PLAN: 7. Laundry receptacle may not share the bathroom circuit, E3603.4. 8. Justify the air conditioning load specified and verify sufficient service panel size, E3502.2. INTERNATIONAL ENERGY CONSERVATION CODE: 9. The simplified prescribed energy values for a ceiling cavity is R=30. Mass wall requirement is R=4 when 50% of insulation is exterior and R=6 when applied interior, N1102.1. Provide the prescriptive insulation values or provide an energy calculation (such as ResCheck) for the project. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/14/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 01/14/2010 | SUE REEVES | REJECT SHELF | Completed |