Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM03167
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/12/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 1-12-10 Activity: T09CM03167 Address: 627 N Norton Ave Applicant: Bill Clark Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FOUNDATION PLANS: 2. Provide a note for termite treatment, R320 as amended. ELEVATIONS: 3. Provide an attic space ventilation calculation and note the size and location of all attic vents needed to comply, R806.2. SECTIONS - DETAILS: 4. Specify wall and ceiling covering (interior and exterior). Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. 5. Specify roof slope and roofing type, grade of materials, and method of installation, R905. PLUMBING PLAN: 6. Shower and tub/shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type. 7. Specify water conservation requirements: Water closets = 1.6 gallons per flush, Sinks/ Showerheads = 3 gpm, UPC State Amend. 45-312. 8. Specify the location of the pressure and temperature relief line for the water heater terminating to the exterior facing down between 6 and 24 inches above grade, UPC 608.5. 9. Provide a vent for the kitchen sink, UPC 904. MECHANICAL PLAN: 10. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. ELECTRICAL PLAN: 11. Specify the grounding electrode method and size of the grounding electrode conductor, E3508. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 12/17/2009 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/13/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/13/2010 | SUE REEVES | REJECT SHELF | Completed |