Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T09CM03022
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2009 | RONALD BROWN | ADA | REVIEW | Passed | Not a COT owned/operated property |
| 11/18/2009 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 11/24/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 11/30/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A0; OCCUPANCY LOAD: THERE ARE INCONSISTENCIES IN THE OCCUPANCY CLASSIFICATIONS AND THE OCCUPANCY LOAD. IN THE OCCUPANCY CLASSIFICATION, YOU INDICATE 360 SF OF S-1 OCCUPANCY, AND 1765 SF OF B OCCUPANCY. IN THE OCCUPANCY LOAD CALCULATION, YOU INDICATE AN E OCCUPANCY FOR 954 SF, AND B OCCUPANCY FOR 1171 SF. VERIFY IF WE ARE S-1/B OCCUPANCY CLASSIFICATION, OR E/B CLASSIFICATION. CHANGE THE OCCUPANCY LOAD AS REQUIRED. 2. SHEET A0; OCCUPANCY CLASSIFICATION: IF THIS IS A S-1/B OCCUPANCY CLASSIFICATION, THERE IS NO REQUIRED SEPARATION BETWEEN THOSE AREAS PER THE 2006 IBC TABLE 508.3.3. HOWEVER, IF YOU ARE CALLING THESE AN E/B CLASSIFICATION, A 2 HOUR SEPARATION WALL IS REQUIRED PER THE IBC TABLE. THIS DIRECTLY AFFECTS NOTE 1 OF THESE REVIEW COMMENTS. CLARIFY. 3. SHEET A1; FLOOR PLAN: THE DOORS INTO THE MEN'S AND WOMEN'S RESTROOMS NEED TO MEET THE REQUIREMENTS OF ICC/ANSI A117.1-2003, SECTION 404.2.3 AND FIGURE 404.2.3.1(a) FOR MANEUVERING CLEARANCES AT DOORS. PROVIDE A DIMENSION ON THE FLOOR PLAN INDICATING THE REQUIRED 18" DIMENSION IS MET. 4. SHEET A3; HEADER SCHEDULE: THE HEADER DETAIL INDICATES BEARING ON WOOD STUDS, WHILE THE PLAN INDICATES MASONRY WALLS. ARE THERE ANY NEW WOOD HEADERS ON THIS PROJECT, OR SHOULD ALL NEW HEADERS REFERENCE DETAIL 2/A3? CLARIFY. 5. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 12/02/2009 | ERIC NEWCOMB | ZONING HC | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
| 12/04/2009 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/15/2009 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/15/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported. Reference: Sections 310.0 and 314.5, UPC 2006. 2. Provide a drain for the watertight pan under the water heater to an approved location. Reference: Section 508.4, UPC 2006. 3. Provide a vacuum relief for storage-type water heaters located above any fixture outlets. Reference: Section 608.7, UPC 2006. |
| 12/15/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide structural details to show how the fan coils are being connected to the building structure. Reference: Section 302.1, IMC 2006. 2. The building occupancy analysis on sheet A0 is unclear. If the occupancy is actually S1/B/E, a 2-hour fire separation will be required between the S1 and E/B occupancy, affecting the duct penetration of the garage. Resolve with the architect and modify as required. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/07/2010 | SUE REEVES | APPROVAL SHELF | Completed |
| 01/07/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |