Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T09CM02864
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/06/2010 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 01/13/2010 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: 19324 N. Corte El Rancho T09CM02864 Convert residence to Bed & Breakfast Residential Building Plan (2nd Review) TRANSMITTAL DATE: January 20, 2010 1. In regards to the Special Exception for this use provide the following information on the plan; Special Exception number, Date of Approval, Any Conditions of Approval. Additional comments may be forth coming once the conditions of approval are provided. 2. Once the Special Exception information is provided on the plan Zoning is will provide an over the counter review. Please call or email to schedule an appointment for the over the counter review. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\grading\t09cm0864.doc |
| 01/22/2010 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T09CM02864 Rev 1 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007; the 2006 UPC with amendments on 7/10/2007; effective 1/1/2007 the Inclusive Home Design; starting 3/1/2009 Solar Water Preparation and 7/1/2009 Solar Photo-Voltaic Preparation. All new SFR and duplex plans should reference these codes. Amendments to adopted codes are at the City web-site http://www.tucsonaz.gov: Planning, Building, & Business; under the Building topic; Building Ordinances and Codes; Building Codes SECTIONS - DETAILS: 1. Exterior framed walls require ½" diameter anchor-bolts, R403.1.6. Revise Detail 3/3 showing expansion bolts. PLUMBING PLANS: 1. Sheet 5.1 clarifies the new 1" gas branch line connection to the existing gas line. The developed length of 35' is misstated. The new developed length is the pipe length from the meter to the furthest appliance (furnace 1). A 1" line over 200' will only support a 119 BTU demand. UPC 1217.2 & Table 12-8. Also, the existing gas pipes will require upgrading unless the proposed appliances are connected directly to the meter. Please provide a code compliant design. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/26/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 01/26/2010 | SUE REEVES | REJECT SHELF | Completed |