Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T09CM02827
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/22/2009 | SREEVES1 | ADA | REVIEW | Passed | |
| 10/23/2009 | DAVE MANN | FIRE | REVIEW | Approved | Sprinkler design per NFPA 13D would be acceptable. |
| 10/27/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Graphically show on the landscape plan the number of parking spaces DS 2-07.2.2.A.1.c 2. A 5' wall is required to screen adjacent residential properties from the vehicle use area per LUC Table 3.7.2-I. 3. If a new development is using an existing screen on an adjacent property to meet screening requirements, a copy of the recorded covenant locating the existing screen(s) on adjacent property is required. Include a copy of the Joint Use Agreement. Indicate the docket & page on the site and landscape plans. 4. A 6' screen is required for refuse storage within 100' ft of an adjacent street LUC Table 3.7.2-I. 5. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. 6. Additional comments may apply. |
| 10/27/2009 | STEVE SHIELDS | ZONING | REVIEW | Denied | 5DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Reza Homes T09CM02827 Site Plan (1st Review) TRANSMITTAL DATE: July 31, 2009 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance. 2. D.S. 2-02.2.1.A.6 There appears to be porches and second floor overhangs proposed. Clearly identify what the dashed lines are that are shown on the plan. Provide building elevations. 3. D.S. 2-02.2.1.A.7 Once the above requested building elevations are provided Zoning can verify that all building setbacks are met. 4. D.S. 2-02.2.1.A.8 Provide a typical parking space detail for vehicle parking space that includes a dimension for the proposed wheel stop, see D.S. 3-05.2.3.C.2. 5. D.S. 2-02.2.1.A.12 As access to the vehicle parking spaces is provided via a parking area access lane (PAAL) per D.S. 2-08.4.1.F the sidewalks or pedestrian refuge areas may not be located between any motor vehicle parking space and the PAAL providing access to that space. That said the proposed location of the pedestrian access running along the west side of the proposed vehicle parking spaces needs to be relocated. 6. D.S. 2-02.2.1.A.12 Provide a backup spur at the north end of the proposed PAAL that meets the requirements of D.S. 3-05.2.2.D 7. D.S. 2-02.2.1.A.13 If applicable show the location, type, size, and height of existing and proposed signage on the plan. 8. D.S. 2-02.2.1.A.20 If applicable show all easements of record must be graphically shown on the plan together with recording docket and page reference. 9. D.S. 2-02.2.1.A.25 If applicable show existing and proposed lighting layout and type. 10. D.S. 2-02.2.2.A Provide a RESIDENTIAL DENSITY CALCULATIONS that provides the number of units allowed and provided. Zoning acknowledges that the number allowed was provided. 11. D.S. 2-02.2.2.A.2 Under "SITE DATE" there are two buildings shown, 'A' & 'B' but there are three (3) buildings shown on site, please clarify. Show the floor area for all three building on the plan. 12. D.S. 2-02.2.2.A.3 Provide a lot coverage calculating that meets the requirements of LUC Section 3.2.9 LOT COVERAGE. 13. D.S. 2-02.2.2.A.4 The provided vehicle parking spaces calculation is not correct. Per LUC Section 3.3.4. RESIDENTIAL USE GROUP, Multifamily Dwellings, 0-70 units/acre, Three Bedrooms 2.25 spaces per dwelling unit. This said three (3), three (3) bedroom units require 3 x 2.25 = 7 vehicle parking spaces with 9 vehicle parking spaces provided. 14. Depending on how the above comments are addressed addition comments may be forth coming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t09cm02827 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents. |
| 10/28/2009 | ANDREW CONNOR | NPPO | REVIEW | Approved | No Protected Native Plants will be affected. |
| 11/10/2009 | RONALD BROWN | ZONING HC | REVIEW | Denied | 12 NOVEMBER 2009 T09CM02827/REZA HOMES REVIEWED BY RON BROWN ACCESSIBLE REVIEW 2006 IBC/ICC 117.1 REZA HOMES 1. PROVIDE A NOTE OF THE DRAWING THAT ALL ACCESSIBLE STANDARDS WITHIN PRIVATE PROPERTY ARE GOVERN BY THE 2006 IBC/ICC ANSI 117.1 2. PROVIDE AND IDENTIFY ACCESSIBLE ROUTE THROUGHOUT SITE TO ALL BUILDINGS AND PARKING FACILITIES AS PER 2006 IBS SECTION 1104 AND ICC 117.1 SECTION 402. A. PROVIDE SPOT GRADES OF ALL ACCESSIBLE ROUTES OR OTHER WISE SHOW SLOPE COMPLIANCE WITH SECTION 403.3. 3. SHOW ALL CURB RAMPS AND SIDEWALK RAMPS REQUIRED WITHIN THE PRIVATE PROPERTY BOUNDARIES COMPLYING WITH ANSI STANDARDS, SECTION 405 AND 406. 4. AT ALL REQUIRED MARKED CROSSINGS; PROVIDE PROPER RAMPS AND DETAILS. PROVIDE LARGE SCALE DETAILS SHOWING ALL DIMENSIONAL DETAILS AND REQUIRED ACCESSORIES, GRADES, DETECTABLE WARNINGS AND FINISHES IN COMPLIANCE WITH ANSI, SECTIONS 405 AND 406. 5. PROVIDE ACCESSIBLE PARKING SPACES, SIGNAGE AND ISLE AS PER 2006 IBC, SECTION 1106 AND ICC (ANSI) SECTION 502. SHOW ALL DEMINISIONS AND SIDE WALK OR CURB ACCESS RAMPS AS PER ICC 117.1; SECTION 405 AND 2006 IBC, SECTION 1010. PROVIDE A LARGE SCALE DETAIL. 6. PROVIDE ACCESSIBLE PARKING SIGN DETAIL. END OF REVIEW |
| 11/12/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The rim elevation of the next upstream sanitary manhole (2377.59') is higher than the first floor elevation (2377.00'). Provide backwater valves per Section 710.1, UPC 2006, as amended by the City of Tucson. 2. Clarify how water will be supplied to the three buildings, i.e. single or multiple meters. Reference: Section 103.2.3, UPC 2006. |
| 11/18/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: November 19, 2009 SUBJECT: 3 Single Family Residences TO: a.s.i architects studio inc. LOCATION: 1447 E Blacklidge Drive, T13S, R14E, Section 31, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09CM02827 (First Review) RESUBMITTAL REQUIRED: Site Plan, Grading Plan and Drainage Report SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the Site Plan, Grading Plan and Drainage Report. Site Plan: 1. The most recent aerial photo of the building does not match what is depicted on the site plan. Please modify site plan to represent actual footprint of existing buildings and/or clarify. Show existing buildings on site plan. Add note in regards to whether or not the existing buildings are to remain or to be demolished. Add activity number to site plan of any demolition permits. 2. Please label lot dimensions to accompany bearings along south property line per D.S. 2-02.2.1.5 3. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. 4. DS Sec.2-02.2.1.A.11: Revise the site plan to show the minimum 12-foot separation that is required between adjacent driveways. Show and label the existing driveways adjacent to the site and verify the 12-foot minimum width. Refer to Tucson Code (TC) Chapter 25-39 for curb cut and driveway requirements. 5. DS Sec.2-08.4.1.c: A sidewalk will be provided adjacent to any parking space accessed by a PAAL where the space is located on the same side of the PAAL as any building and no other parking spaces or PAALs intervene. Provide 4' sidewalk - dimensions and label appropriately. 6. D.S. 2-02.2.1.A.12 Provide a backup spur along the north end of the proposed PAAL for maneuverability from parking spaces per D.S. 3-05.2.2.D. 7. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. 8. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. 9. Please list estimated cut & fill quantities on the site plan per D.S. 2-02.2.1.17. 10. Label dimensioned right-of-way and indicate whether dimension is existing or future. If existing and future right of way are the same please indicate on plans per D.S. 2-02.2.1.19. 11. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Blacklidge Drive (I-660). 12. DS Sec.2-02.2.1.A.19: Dimension the sidewalk along Blacklidge Drive. 13. Verify that all easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 14. Provide City Field Book and page number for benchmark per D.S. 2-02.2.1.23. Provide contour interval on plan, preferably with north arrow and scale. 15. Verify that all fences, walls, or vegetation for screening and sight visibility have been indicated by type, material, height, location and spacing per D.S. 2-02.2.1.27. 16. Show site plan and grading plan number in the lower right hand corner of each sheet accordingly per D.S. 2-02.2.1.29. 17. DS Sec.2-02.2.1.A.32: the detail with dimensions for refuse container on the site plan indicated that there will be curbside pick up. Enclosures are required to have a minimum inside clear dimension of 10 feet by 10 feet between steel bollards that are required between the container and the enclosure's rear and sidewalk. Refer to DS Sec.6-01.4.2 for specifications and requirements on access, placement of containers, bin enclosure and construction. For curbside pickup a letter of approval will be required from COT Environmental Services and a Development Standard Modification Request (DSMR) may be required prior to site plan approval. 18. DS Sec.2-02.2.1.A.32: Label and show the maneuverability for refuse vehicles in plan view at the proposed refuse container location. Current positioning of trash area does not allow for 14' X 40' clear approach, show access dimensioning to proposed trash enclosure. 19. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please indicate off site elevation within 100' of property line. 20. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 21. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. 22. List the consulting drainage engineer on the plans with the pertinent information. 23. Revise site plan key note to read: "Depress all landscaped areas 6" maximum for water harvesting". 24. North parking space adjacent to 3'4" wall, parking space is required to be 10'. 25. Provide standard detail number for site plan key note 11. 26. Please clarify the purpose of site plan key note 9. 27. Please provide dimension of sidewalk in site plan key note 20. 28. Call out peak discharges entering and exiting the site. 29. Check with ADA, Ronald Brown to verify that no handicap access ramps are required along Blacklidge. If they are required, revise accordingly. 30. Black markings within identified curb should be called out. Are these depressed curbs? 31. Provide proof that water will continue north onto public street north of northern adjacent parcel. Must show that there is no adverse impact. 32. Additional comments may be forthcoming. Drainage Report: 1. Backwater analysis shows elevations in the range of 2707 and site/grading plans indicate 70 elevations. Please review and revise accordingly. 2. Provide floodplain limits and water surface elevations from drainage report on site/grading plan. 3. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/20/2009 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 11/20/2009 | SUE REEVES | REJECT SHELF | Completed |