Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09CM02813
Parcel: 122173470

Address:
3232 E LEE ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM02813
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/11/2010 STANTEC 2ND PARTY REVIEW REVIEW Denied February 11, 2010


To: Ernie Duarte, Acting Building Official
City of Tucson Development Services Department
201 N. Stone Avenue, First Floor
Tucson, Arizona 85701

Re: Dutton Residence – Remodel/Addition
City of Tucson No. T09CM02813
Stantec Project No. 816-30015 (10-002)




Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back-check time, we request that you please provide revised plans and calculations, clouding any changes, along with a written response to each of the noted items indicating the action taken.

SCOPE OF REVIEW:

The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2006 International Residential Code [IRC], the Outdoor Lighting Code and the Inclusive Home Ordinance. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL:

There are no general comments to be addressed.

ARCHITECTURAL:

There are no architectural comment to be addressed.

STRUCTURAL:

The following previously made comment has been partially addressed. Detail 10 on Sheet 4 shows a beam and post being added to support a new framed roof over existing framing. The post is bearing on a “non-bearing” end wall (note the existing single top plate and existing roof framing direction); this will not work. The post will have to extend all the way down to the foundation and a footing provided. Everything has been addressed except the connection of new 4x6 post located in the wall to both the sill/foundation and to the double top plate and 4x6 post above.

MECHANICAL:

There are no mechanical comments to be addressed.

PLUMBING:

There are no plumbing comments to be addressed.

ELECTRICAL:

There are no electrical comments to be addressed.

-End of Review-



If you have any questions, please call (520) 750-7474.

Sincerely,
Stantec Consulting Inc.



Joel Svoboda
Associate

JES:jes

Attachments: None

Final Status

Task End Date Reviewer's Name Type of Review Description
02/16/2010 DELMA ROBEY OUT TO CUSTOMER Completed
02/16/2010 SUE REEVES REJECT SHELF Completed