Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM02794
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 1-19-10 Activity: T09CM02794 Address: 317 E 5th St. Applicant: Therese Brown Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans including revisions, details and calculations in accordance with the rules of the State Board of Technical Registration. INCLUSIVE HOME DESIGN: 3. Provide all switches, receptacles, and controls within 48 inches of the floor but not less than 15 inches above the floor (To include thermostat controls), 1003.9. FLOOR PLANS: 4. Specify safety glazing in hazardous locations (kitchen window within 24" of door), R308.4. 5. Individual dwelling units in duplexes must be separated by a 1-hour firewall from floor to bottom of roof sheathing (separation must extend to end of building, including porch) , R317.1. PLUMBING PLAN: 6. Show the size and location of all cleanouts (two-way cleanout required within 2' from the building at the lower end), P3005.2. 7. Provide vent for kitchen sink in unit #2, P3101.1. ELECTRICAL PLAN: 8. Show receptacle outlets at wall spaces 2' or more so that no point along the wall (excluding door openings) is more than 6' from a receptacle outlet, E3801.2. 9. Bathrooms require a separate 20-amp circuit (may not share smoke detector circuit), E3603.4. 10. Exterior outlets at grade level shall be provided at both the front and back of the dwelling, E3801.7. These outlets shall be GFCI protected E3802.3. 11. Bedroom outlets shall be protected with combination-type arc-fault breakers (including smoke detectors), E3802.12. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 12/17/2009 | GERRY KOZIOL | WWM | REVIEW | Denied | needs 5th floor wastewater credit evaluation |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/26/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |