Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T09CM02794
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/20/2009 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Terry Stevens, Lead Planner PROJECT: T09CM02794 317 E. 5th St. Porch and Remodel TRANSMITTAL: October 20, 2009 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This site is located in the HR-3 Zone (LUC Section 2.3.4.2.A.1). The Development Designator is "P" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator is CC (LUC Section 3.2.6.4). The required setback for interior lot lines is the greater of ten (10) feet or three quarters (3/4) the height of the structure's wall facing the property line (LUC Section 3.2.6.4). The required setback is ten (10) feet to the west property line and the proposed setback is zero(0) feet. The required street perimeter yard setback is the greater of twenty (20) feet or one and one half (1 ½) time the height of the structure (LUC Sec.3.2.6.5.A) The required street perimeter yard setback is twenty (20) feet. The proposed street setback is eighteen (18) feet. DDO and HPZ review required. |
| 12/15/2009 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review | |
| 12/15/2009 | CPIERCE1 | NPPO | REVIEW | Needs Review | |
| 12/15/2009 | CPIERCE1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |