Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM02757
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/08/2010 | RONALD BROWN | BUILDING-RESIDENTIAL | REVIEW | Denied | GENERAL: 1. There are several sheets in this submittal package that have lettering smaller than the required 3/32" height. Please reconfigure all fonts to be no less than 3/32" in height, (upper and lower case) and resubmit. 2. Please provide consecutive sheet numbers on each construction drawing, R106.1.1. FLOOR PLANS: 3. Identify ceiling heights in all areas. Note average height at sloped ceiling areas, R305.1. 4. Show the location of attic access min. 22"x30", R807. 5. Show fireplace location, hearth size and materials, R1001 or R1004. Provide fireplace cut sheets or note the requirement for deferred submittal approval prior to installation. Show the flue on the elevations. 6. Tub/shower enclosures require nonabsorbent wall surface min. 6’ above the floor and fiber-cement board backing, R307.2, R702.4.2. FOUNDATION PLANS: 7. Please provide a landing or floor surface at all exterior doors, R311.4.3. ELEVATIONS: 8. Provide an attic space ventilation calculation and note the size and location of all attic vents needed to comply, R806.2. 9. Chimney: min 2’ above any roof point within 10’, not less than 3’ above penetration, R1003.9. Show the fireplace flue. SECTIONS - DETAILS: 10. Detail all over-framing connections for intersecting pitched roof assemblies. Provide a minimum opening of 2" by 30" for access and ventilation between over-framed assemblies (>30 S.F.), R807. 11. Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. ELECTRICAL PLANS: 12. Electrical work shall comply with 2006 IRC chapters 33 - 42. 13. Provide equipment rated for 22,000 AIC short circuit protection when the underground cable length is less than 45 feet, 2006 Electric Service Requirements TEP SR-510. 14. Bedroom outlets shall be arc-fault protected (receptacles, lights, and smoke detectors), E3802.12. MECHANICAL PLANS: 15. Mechanical shall comply with 2006 IRC chapters 12 - 24. 16. Show supply and return ducts with minimum R-8 insulation, R1103.2.1. 17. Designate the location, capacity and fuel type of the heating and air conditioning equipment. Designate the locations of each supply register, return air grill and all ductwork. 18. Provide an equipment specification list, M1302.1. 19. Show the condensate line and secondary for HVAC unit, M1411.3. OUTDOOR LIGHTING CODE 20. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). INTERNATIONAL ENERGY CONSERVATION CODE: 21. Provide a note requiring the insulation certificate shall be posted in the electrical distribution panel before final inspection, N1101.8. END OF REVIEW |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/16/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 04/16/2010 | SUE REEVES | REJECT SHELF | Completed |