Permit Number: T09CM02738
Parcel: 12308024C

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T09CM02738
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/18/2010 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: May's Counter Restaurant
T09CM02738
Site Plan (4th Review)

TRANSMITTAL DATE: February 18, 2010

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the areas of expansion and revision to the last approved site plan.

2. D.S. 2-02.2.1.A.7 Per LUC Section 3.2.6.4, C-1 Zone, Food Service, subject to: Sec. 3.5.4.6.A and .C, Development Designator "28", Perimeter Yard Indicator "DD" the required perimeter yard setback is 1-1/2 the height of the exterior wall. Exterior wall height 8'-0" therefore the required perimeter yard setback from the proposed shed covering the new beer cooler to the north property line is 12'-0", proposed setback, 7'-0". A Design Development Option (DDO) will need to be processed and approved prior to approval of the site plan if the 8'-0" perimeter yard setback is to remain as shown on the site plan.

Depending on how the above comments are addressed addition comments may be forth coming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t09cm02738

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
02/18/2010 BIANCA RAMIREZ ENGINEERING REVIEW Denied 2/18/10

Reviewed revised comments over the counter with Lisa B. All comments appear to have been addressed. Unable to approve until DDO has been reviewed and approved.

Verify site revision in regard to letter.

Bianca
02/18/2010 ERIC NEWCOMB ZONING HC REVIEW Approved
02/24/2010 MARTIN BROWN FIRE REVIEW Approved
03/01/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/03/2010 GERARDO BONILLA OUT TO CUSTOMER Completed
03/03/2010 SUE REEVES REJECT SHELF Completed