Permit Number: T09CM02526
Parcel: 14108528A

Review Status: Completed

Review Details: SITE

Permit Number - T09CM02526
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2009 RBROWN1 ADA REVIEW Passed Not a COT owned/operated property
09/28/2009 DAVE MANN FIRE REVIEW Approved
09/30/2009 RONALD BROWN ZONING HC REVIEW Denied 1. For the total amount of parking spaces (72) shown on the site plan, 3 accessible parking spaces are required as per 2006 IBC, Table 1106.1. Please add 3 accessible parking spaces and aisles.
2. Please provide an accessible route to the public right of way pedestrian way. Reference Zoning comments for the type of finishd material to be used for this route.
3. Please show large scale details of all accessible parking, marked crossings, curb ramps, sidewalk ramps, signage,slope requirements, access from parking aisles to accessible route and detectable watrnings as per ICC (ANSI) Sections 405, 406 and 502.

END OF REVIEW
10/02/2009 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: T09CM02526
____ S. Memorial Place
Site Plan

TRANSMITTAL DATE: 10/02/09

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project is a stand alone parking lot, not a part of 6692 S. Memorial Place. A separate address will be required for this project. A change of address will also be required for the permitting process.

2. Provide a detail of both a handicap parking space and standard parking space.

3. Wheel stop curbs will be required for all parking spaces along the south property line I order to prevent overhanging the property line by vehicles. Clearly indicate location of all wheel stops on the site plan and provide dimension from the front of the parking space on the details.

4. A clear area of 3' is required behind a backup spur. The northwest corner backup spur does not appear to meet this requirement.

5. Standard handicap and van accessible parking spaces are required based on the number of provided parking spaces. The number required for this project is a minimum of 2 standard handicap parking spaces and 1 van accessible parking space.

6. Provide an accessible pedestrian circulation path from the handicap parking spaces to the sidewalk located in the right of way.

7. It appears that pedestrian circulation is being provided with the lot adjacent to the south (existing crosswalks). A pedestrian cross access agreement will be required. Provide on the site plan the recording docket and page of the pedestrian cross access agreement. Provide for review a copy of the cross access agreement.

8. Add as a note that any future development will be required to meet the criteria of the AEZ overlay for the AHD, NCD-70 and ADC-2.

9. Add the annexation case number (C15-95-16) on all sheets in the lower right corner.
If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\T09CM02526.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
10/05/2009 ANDREW CONNOR NPPO REVIEW Approved Exception
10/05/2009 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Landscaping is required along retention basin side slopes, bottom and periphery. Plant materials used in basins shall withstand periodic inundation. A minimum of 20 trees per acre must be provided, 33% of tress shall be 24" box or larger. A minimum of 2 shrubs for each tree is required per DS 10.01. Revise landscape plan to include basin(s) additional treatment.

2. All landscape areas will be depressed to accept water flow from roofs, PAAL, and parking areas. Show by detail or spot elevations how landscape areas will accommodate water harvesting.

3. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.
10/22/2009 PAUL MACHADO ENGINEERING REVIEW Denied To: Peter Solonga, P.E. DATE: October 26, 2009
199 E. Fort Lowell Rd.
Tucson, Arizona 85705

Subject: UFC Aerospace Corp., 6692 S. Memorial Pl.
Site plan T09CM02526 (First Review)
T15S, R15E, Section 18

RESUBMITTAL REQUIRED: Site/Grading Plan.

The Site Plan (SP)/Grading Plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
3. Dimension the ingress/egress on both plans.
4. Call out what plat (Bk. and Pg.) the easements where recorded on when referring to "per plat" on the plan.
5. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.

Grading Plan:
1. Please include a response letter to the comments along with the corrected copies of the GP.
2. A number of the general grading notes call out for SWPPP measures, will there be a SWPPP submitted? If not, remove any notes pertaining to inspections or activities related to SWPPP inspections from the grading notes. However, some of the BMP of a SWPPP shall be shown on the grading plans because of the direct discharge in the existing Det./Ret. basin. The BMP shall include but are not limited to a sediment trap at the discharge point, a stabilized entrance and a concrete washout area.
3. Show curb openings along the south border of the parking lot to accept off-site water and show DC openings for the islands to accept water for water harvesting.
4. Show a standard bollard at the center of the 6' curb opening for the rip-rap channel.
5. Although the fabric filter for the trapezoidal channel is called out in the key note, the filter fabric should be shown on the detail 2 of 2.
6. List administrative address/site address on the plans.
7. List the SP number (T09CM02526) on all the sheets.
8. List all Cut and Fill quantities in cubic yards. If both are 0 cy, please list. There is a discrepancy between the SP and GP regarding the amount of earthwork needed on this project (cut). Revise as required.
9. Show cross section with transverse and longitudinal slopes of the parking lot.

Drainage Statement:
1. The DS has been accepted by engineering.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/6692 S. Memorial Place Site-Grad
10/26/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
10/28/2009 CINDY AGUILAR OUT TO CUSTOMER Completed