Permit Number: T09CM02509
Parcel: 12111190A

Address:
4826 E PIMA ST

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T09CM02509
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/16/2009 MARTIN BROWN FIRE REVIEW Approved
09/16/2009 ERIC NEWCOMB ADA REVIEW Passed
09/16/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
09/16/2009 ERIC NEWCOMB ZONING HC REVIEW Approved
09/16/2009 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
09/17/2009 JIM MILITELLO MECHANICAL-COMMERCIAL REVIEW Denied 1. Return air cannot be recirculated from a kitchen.
2. Parapet needs to extend min. 30" beyond equipment within 10' of roof edge or install guard rails.
3. Provide min. 18" clearance between top of hood and wood framed ceiling or provide 2 layers of fire wrap on top of hood.
4. Clarify the construction of the grease duct.
5. Specify manufacturer and model of exhaust fan, hood, and makeup air unit.
09/17/2009 STEVE SHIELDS ZONING REVIEW Approved
09/17/2009 JMILITE1 WATER REVIEW Approved
09/18/2009 CPIERCE1 ELECTRICAL-COMMERCIAL REVIEW Needs Review
09/18/2009 CPIERCE1 WWM REVIEW Needs Review
09/18/2009 CPIERCE1 PLUMBING-COMMERCIAL REVIEW Needs Review
09/18/2009 CPIERCE1 ENGINEERING REVIEW Needs Review