Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09CM02461
Parcel: 113060300

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T09CM02461
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2009 GERRY KOZIOL WWM REVIEW Approved
10/06/2009 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS T09CM02461

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007; the 2006 UPC with amendments on 7/10/2007; effective 1/1/2007 the Inclusive Home Design; starting 3/1/2009 Solar Water Preparation and 7/1/2009 Solar Photo-Voltaic Preparation. All new SFR and duplex plans should reference these codes. Amendments to adopted codes are at the City web-site http://www.tucsonaz.gov: Planning, Building, & Business; under the Building topic; Building Ordinances and Codes ; Building Codes

FOUNDATION PLANS:

1. Show or note a 6" minimum separation of untreated exterior posts, R319.1.4 exception 1.
2. Show compliance with termite treatment, R320 as amended.
3. Note the grade away from foundations shall fall min 6" within the first 10', R401.3.
4. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state an assumed value (1500 PSF max.) per Table R401.4.1 if a soils report is not provided.

FLOOR PLANS:

1. Show that each water closet is located in a clear space not less than 30" wide (centered 15" from finished wall or fixture), R307.1.
2. Revise the exterior stair showing 7 ¾" maximum riser height, R311.5.3), and 36" handrail height R311.5.6.1.

STRUCTURAL PLANS:

1. Provide complete roof framing plan with currently available joists, R301.1. The LPI 30 series is not listed in the 2009 catalog.
2. Show floor joist size, spacing and span consistent with R505.
3. Note the size and weight of the HVAC load on the roof framing plan for verifying the joist load carrying capacity, M1401.
4. Specify steel lintels (if used) to support imposed load, R606.10.
5. Note the 2x12 ledger anchorage or provide an engineer's calculation, design and seal for ledger bolt size and spacing exceeding Figure R606.11 (1).
6. Show design compliance with all appropriate sections of R611 with details of Mikey Block connections and material sizes.
7. Provide interior stairway connection details and stringer sizes. Pre-fabricated metal stair shall have manufacturer's specifications attached to plans showing code compliance, R301.1.3.
8. Field welded connections require special inspections. If used, a special inspection request must be included with the permit application, UAC306.1.5.

SECTIONS - DETAILS:

1. Specify all ledgers connected to masonry walls with 3x material, R606.11.
2. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d.
3. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2.

PLUMBING PLANS:

1. Reference the 2006 Uniform Plumbing Code for the Plumbing design.
2. Note and specify all piping materials, UPC 301.1.1.
3. Show a pressure and temperature relief valve at the water heater. A metallic T&P line must terminate at the exterior between 6 and 24 inches above grade and must terminate facing down, UPC 608.5.
4. Provide water hammer arresters wherever quick-closing valves are installed in a water distribution system. The devices should conform to ASSE 1010-2004. Water hammer arresters are required for clothes washer water connections, UPC 609.10.
5. Provide pipe sizes (diameter & length), average pressure and a complete fixture unit schedule UPC 610.8, Table 6-6.
6. Show the evaporative cooler on the plan.
7. Show hot and cold water lines with pipe sizes, UPC 610.8, Table 6-6.
8. Show an individual accessible water supply shut off, UPC 605.3.
9. Show the exterior stairway floor drain and vent size on the DWV Isometric, UPC 103.2.
10. Protect any drainage piping serving fixtures having flood level rim located below the elevation of the next upstream manhole cover of the public sewer with a backwater valve, UPC 603.3. Note and specify the location and type on plan.
11. Show a two-way cleanout at the building exterior, at 100' intervals and at change of direction exceeding 135 degrees, UPC 719.0.

MECHANICAL PLANS:

1. Show supply and return ducts with minimum R-8 insulation (includes vented attics) except when completely located inside the thermal envelope, R1103.2.1. Show R-4.2 insulation when ducts are located in an unconditioned space (chase) inside the thermal envelope, IECC 503.2.7 (City of Tucson Amended).
2. Show dryer vent size and location for venting to exterior with maximum length of 25' including consideration of bend reductions, M1502.
3. Provide return air duct size meeting minimum requirements of 72 SQ IN/ ton, M1602. Minimum duct/register size: heat pump or air conditioner - 6 SQ IN per 1,000 BTU, M1403.1 (1 ton cooling = 12,000 BTU).

ELECTRICAL PLANS:

1. Provide an electrical riser diagram, E3303. Note the grounding and bonding method, E3507. Metallic gas lines must be bonded and shall not be used as the primary grounding method, E3508.
2. Provide a grounding electrode on the Riser Diagram for the sub-panel, E3507.3.
3. Provide an Electrical service utility plan coordinated with Tucson Electric Power.
4. Tucson Electric Power requires a 2½" diameter service conduit, TEP SR-305.
5. Show the location of the panel on the Electrical Plan, E3501.6.2 & E3605.8.
6. Provide electrical load calculations for determining the service panel size, E3502.2.
7. Designate the circuit number at the location of each light fixture, receptacle, appliance and equipment disconnect switch, E3603.5. Show Heat Pump disconnect at roof with a GFCI receptacle outlet on the same level within 25', E3801.11.
8. Show one 20 AMP branch circuit in the laundry area; this circuit shall not serve other locations, E3603.3 and 3801.8. This circuit may be a 240 volt branch line.
9. Note that combination type arc-fault circuit interrupter shall protect bedroom outlets including receptacles, lights and smoke detectors, E3802.12.
10. Show or note a disconnect means or a locking breaker for the water heater, E4001.5.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/16/2009 DELMA ROBEY OUT TO CUSTOMER Completed
10/16/2009 SUE REEVES REJECT SHELF Completed