Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T09CM02362
Parcel: 13821022A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM02362
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2010 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
01/08/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. The Watts N36-M1 vacuum relief is to be installed in the CW supply line "with or above the highest point of the tank" according to its listing material. Note that note 1 in detail 2/P3.2 still calls for the installation of a pressure vacuum breaker; where will it be installed? Reference: Sections 302.2, 608.13.5, and 608.15.4, IPC 2006.
2. The listing information for the proposed water meter for use with the solar water heater did not indicate if it was NSF-61 certified; is it? Reference: Section 303.2, IPC 2006.
3. Details 5/P3.1 and 6/P3.1 show the CW and the solar HW entering WH-1 with only shut off valves for control. The specified water heater controls the delivered water temperature only by increasing its temperature, not reducing it. Show how the hot water delivery temperature from the tankless water heaters is to be limited to a maximum of 140 degrees Fahrenheit. Reference: Section 501.6, IPC 2006.
01/28/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
12/23/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SEE PROJECT T09CM02359 BUILDING COMMENTS.
12/24/2009 JASON GREEN ENGINEERING REVIEW Approved
12/24/2009 ERIC NEWCOMB ZONING HC REVIEW Denied 1. SEE PROJECT T09CM02359 BUILDING COMMENTS.
12/24/2009 TERRY STEVENS ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
05/11/2010 DELMA ROBEY OUT TO CUSTOMER Completed