Permit Number: T09CM02337
Parcel: 11702006A

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T09CM02337
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2009 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 616 E. Speedway Blvd. - Convert existing garage and storage to sleeping qtrs.
T09CM02337
Residential Building Plan (1st Review)

TRANSMITTAL DATE: September 2, 2009

1. The building & site plan have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Per LUC Section 3.2.6.4, HR-2 Zoning, Development Designator "I", Perimeter Yard Indicator "AA" The required perimeter yard setback to the south property line is 6'-0" or 2/3 the height of the exterior building wall. Based on an exterior building wall of 10'-6" the required perimeter yard is 7'-0", proposed perimeter yard is 1'-0".

3. Per LUC Section 3.2.6.5.A the required perimeter yard setback to the east, or side street, is 10'-0", proposed perimeter yard is 2'-0"

4. Based on the porch addition, Historic Review is required for this project.

5. Zoning will re-review the plan on the next submittal. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t09cm02337.doc
09/02/2009 SSHIELD1 NPPO REVIEW Passed
11/10/2009 CAGUILA1 BUILDING-RESIDENTIAL REVIEW Needs Review
11/10/2009 CAGUILA1 WWM REVIEW Needs Review
11/10/2009 CAGUILA1 ENGINEERING REVIEW Needs Review