Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T09CM02266
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/15/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: December 15, 2009 SUBJECT: Site Plan TO: A23 Studios (Jose) LOCATION: 4261 E Irvington, T14S, R14E, Section 34, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09CM02266 (Fourth Review) RESUBMITTAL REQUIRED: Site Plan, Drainage Report SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the Site Plan. Site Plan: 1. Complied. 2. Complied 3. Complied 4. Complied 5. Complied 6. Complied 7. Complied 8. DS Sec.2-02.2.1.A.12: Revise the site plan to show the required 6-foot wide sidewalk with curb along the street frontage of Irvington Road. Per the adopted Mayor and Counsel policy all sidewalks along MS&R right-of-ways for arterial and collector streets require 6-foot wide sidewalks. Response: Irvington is an arterial street - 6' constructed sidewalk is required. Revise plan to show sidewalk to be constructed. 9. Complied 10. Complied 11. Complied 12. Complied 13. Standard Note: Grading permit will be required. 14. Complied 15. Complied 16. Complied 17. Complied 18. Complied 19. Complied 20. Complied 21. Complied 22. Complied 23. Complied 24. Complied 25. Complied. 26. Standard Note: Be advised a permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 27. Show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the driveway, if applicable. Response: Include information from revised Drainage Report showing offsite Q100 floodplain limits. (See Drainage Report Comments) Response 12/15: Awaiting revised Drainage Report. 28. Complied 29. Complied General Note: For any development with 50 cy of cut or fill will require grading plan and for any site with area of disturbance of one acre or greater a Stormwater Pollution Prevention Plan will be required. It looks from aerial that grading has taken place on site already. "A grading permit and Stormwater Pollution Prevention Plans (SWPPP's) will likely be required for this project. In the event that they are needed, Submit 3 sets of grading and (2) SWPPP's with text, upon completion and submittal of a grading permit application. A grading permit may not be issued prior to site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans". 30. Per site visit on 10/15/09 grading appears to be all the way to the property line. Address the following: a) Complied b) Complied c) Complied d) Complied 31. Complied Response: Complied. 32. Specifically show spot elevations at the property line of driveway to show drainage is being kept on site. Response: Will be reviewed with resubmittal identifying Q 100 per corrections to Drainage Report. Response 12/15: Awaiting revised Drainage Report. 33. Addition comments may be forthcoming. Drainage Report: 1. Complied 2. Include floodplain limits on plan for any 100 year flows that are on site and show how the proposed design considers any impact from jurisdictional floodplain. Response: Complied 3. Include all weather access design if floodplain limits encroach onto property. Response: Will look at this again once Drainage Report has taken Basin B Q100 into account. 4. Complied. Response: Complied. 5. Note that grading design will need to be in compliance with revised hydrology. Please address hydrology prior to submitting grading plan to prevent duplication of comments. 6. Provide cross section to identify limits of the 100-year floodplain. Indicate cross section on site plan. 6. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 12/18/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/18/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |