Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09CM02262
Parcel: 131040300

Address:
4802 E 23RD ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO

Permit Number - T09CM02262
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2009 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T09CM02262
4802 East 23rd Street
Garage addition to SFR


TRANSMITTAL: August 25, 2009


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO).


This Site requires a DDO for the setbacks to the south and west property lines. This site is in the R-2 Zone (LUC Section 2.3.5.2.A.1). The Development Designator is "I" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator AA (LUC Section 3.2.6.4).

The minimum setback to the south property line is the greater of six feet or two-thirds the height of the structure's wall facing the property line. The height of the structure facing south property line is twelve (12) feet, eight (8) inches. The minimum required setback to the south property line is eight (8) feet, six (6) inches. The proposed setback is one (1) foot.

The required side-street setback is ten (10) feet (LUC Section 3.2.6.5.A) from the proposed structure to the property line. The proposed setback is one (1) to the west property line.
08/25/2009 PAUL MACHADO ENGINEERING REVIEW Approved
08/25/2009 MICHAEL ST. PAUL NPPO REVIEW Passed
10/07/2009 DROBEY1 BUILDING-RESIDENTIAL REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/07/2009 DELMA ROBEY OUT TO CUSTOMER Completed