Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T09CM02261
Review Name: SITE
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/27/2009 | RONALD BROWN | ZONING HC | REVIEW | Denied | 1. Provide ramp details in compliance with ICC/ANSI 117.1, Sections 405 and 406. 2. Delete the notherly curb ramp that leads into the vehicle PAAL area. 3. Delete all reference to COT Detail 207. This is for public right of construction only. For all accessible design please use 2006 IBC, Chapter 11 and ICC/ANSI 117.1. 4. Please show slope complinace with ICC/ANSI 117.1, Section 403.3 for all accessible routes, new and existing. Provide spot grades as required. END OF REVIEW |
08/28/2009 | TERRY STEVENS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Terry Stevens Lead Planner PROJECT: T09CM02261 1375 S. Camino Seco Site Plan TRANSMITTAL DATE: 08/28/09 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Provide a site plan clearly indicating PAAL widths. Between parking spaces and at the entrance from Olympic Dr. (both the wide portion and the narrow portion). 2. Provide dimensioned details of the handicap parking spaces and a standard parking space. 3. Wheel stop curbs will be required in the parking spaces to prevent vehicle overhang into the landscape areas. Clearly indicate on the site plan the location of the wheel stops. Note: distance for a wheel stop location is 2'-6" from the front of the parking space. 4. I have attached the last approved site plan to this set of drawings. Please resubmit with these plans attached to the new drawings. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 C:\planning\cdrc\DSD\T09CM02261.doc |
09/03/2009 | ANDREW CONNOR | NPPO | REVIEW | Needs Review | Provide a copy of the last approved landscape plan for reference. |
09/03/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Provide a copy of the last approved landscape plan for reference. 2. Wheel stop curbs will be required in the parking spaces to prevent vehicle overhang into the landscape areas. Identify wheel stops on site plan. 3. Insure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval 4. Additional comments may apply. |
09/16/2009 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Comment not addressed. Indicate material to be used for the water supply to the fountain, and detail the connection to the water service. |
09/16/2009 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | Provide dimensions and radii on the plan. Label the dumpster location to assure accessibility by solid waste trucks. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
09/22/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
09/22/2009 | SUE REEVES | REJECT SHELF | Completed |