Permit Number: T09CM02234
Parcel: 118033910

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM02234
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/30/2010 MARTIN BROWN FIRE REVIEW Approved
07/09/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Approved
07/14/2010 GERRY KOZIOL WWM REVIEW Denied need to apply for a septic permit( need septic design & review fee) OR evaluate exsisting system
07/16/2010 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: July 16, 2010
SUBJECT: Site Plan for Custom Home
TO: George Zazueta
LOCATION: 2461 S San Joaquin Av, T 14S, R 13E, Section 21, Ward 1
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T09CM02234 (Second Review)

RESUBMITTAL REQUIRED: Building Plan and Drainage Report

SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Building Plan and Drainage Report for the above referenced property. Engineering Division does not recommend approval of the Building Plan or the Drainage Report at this time. Please address the following review comments prior to the next submittal.

Further Discussion - Please be advised that any encroachment into the identified floodplain limits will require ERR report and review.

7/16/10
It has been determined that the following is required prior to approval of proposed individual lot development.

1. Grading permit is required for proposed SFR, please submit grading plan for further review.
2. Show interceptor at south side of proposed building with spot elevations to indicate high point/grade break and positive gradient along south side. Per IBC code there shall be a 5% slope from foundation for 10 feet from structure.
3. Show and label grading limits to include septic tank area, disturbance for construction and access area from road.
4. Add as a note to plan: There shall be no disturbance of a 100-year riparian area,
5. Label no disturbance area on plan for floodplain/wash area.
6. Add as note to plan: Any slopes that exceed 3:1 (H:V) shall be constructed with riprap and filter fabric. No slope is to exceed 2:1 (H:V) without being accompanied by a geotechnical report.
7. Sheet C.1 can be renamed as SITE/GRADING PLAN, otherwise submit a separate grading plan with grading permit application.
8. Additional comments may be forthcoming.

Drainage Report

1. Provide north arrow for Figure 2: Aerial map,
2. Identify project location on FEMA Map within Figure 3: FEMA map.
3. In report provide datum used for hydraulic calculations.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Best Regards,
Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
07/16/2010 MICHAEL ST. PAUL ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/02/2010 CPIERCE1 OUT TO CUSTOMER Completed
08/02/2010 SUE REEVES REJECT SHELF Completed