Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T09CM02063
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/05/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
08/11/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. GENERAL: PROVIDE STRUCTURAL CALCULATIONS INDICATING THE EXISTING ROOF STRUCTURE CAN ADEQUATELY SUPPORT THE NEW/REPLACEMENT AC UNITS (AS LISTED ON SHEET M1.1 IN THE 'AIR BALANCE SCHEDULE' AND 'KEY NOTES'). 2. SHEET A5.0; BREAK ROOM ELEVATIONS: VERIFY THAT COUNTER/SINK HEIGHTS IN THE BREAK ROOM MEET ACCESSIBILITY REQUIREMENTS. |
08/12/2009 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Denied | SEE BUILDING COMMENTS. |
08/17/2009 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Approved | 1. The City of Tucson is currently under the 2006 UPC. |
08/17/2009 | RMYERS1 | WATER | REVIEW | Approved | |
08/17/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the ventilation calculations to take into account the different occupancy loads in the project space. Reference: Sections 403.3 and 403.3.2, IMC 2006. 2. If the new rooftop AC units (AC 6-2 and AC 6-3) have a different natural gas input than the units that are being replaced, provide the revised natural gas pipe sizes and piping layout. Include gas pressures and developed pipe lengths on plans. Reference: Section 1217.0, UPC 2006. |
08/26/2009 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
08/26/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
08/26/2009 | SUE REEVES | REJECT SHELF | Completed |