Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU
Permit Number - T09CM01944
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T09CM01944 615 East 1st Street Detached garage for SFR TRANSMITTAL: July 21, 2009 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This site is located in the HR-2 Zone (LUC Section 2.3.5.2.A.1). The Development Designator is "I" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator is AA (LUC Section 3.2.6.4). This site is located in a Historic Preservation Zone (HPZ). Historic review is required (LUC Section 2.8.8.5). The minimum setback for the proposed garage is the greater of six (6) feet or two-thirds (2/3) the height of the structure's wall facing each interior property line (LUC Section 3.2.3.B and 3.2.6.4). The required setback to the north property line is eight (8) feet nine (9) inches (LUC Section 3.2.6.4). The required setback to the east property line six (6) feet eight (8) inches (LUC Section 3.2.6.4). The proposed setback to each property line is four (4) feet. |
| 07/21/2009 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 07/21/2009 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 09/21/2009 | THAUSER1 | BUILDING-RESIDENTIAL | REVIEW | Approved |