Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T09CM01709
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/16/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | December 16, 2009 FLOODPLAIN USE PERMIT # T09OT01737 PROJECT ADDRESS: 10238 E Desert Flower Place APPLICANT'S NAME: Sunny Hennig PROPERTY OWNER: Dave Yiu This parcel lies within a City of Tucson regulated 100 year floodplain. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: Parcel: 114-55-1740; 10238 E Desert Flower Place, Tucson, AZ 85749, TANQUE VERDE TRAILS LOT 9, in a portion of Township 13 South, Range 15 East, Section 35, for the construction of a garage and porch to an existing conforming Single Family Residence. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) The proposed construction of garage and porch to an existing conforming single family residence. The proposed additions are located within an a City of Tucson regulated 100-year floodplain, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance), and is required to meet the minimum elevation requirements of 1' above determined calculated BFE. Per Drainage Statement from "Drainage Statement for proposed scour wall", signed and sealed by Greg Carlson, Dated 12/14/09. Determined base flood elevation on upstream side (Cross Section A), of addition has a determined WSE = 2597.72 (NAVD 88). 4) For purposes of this permit the following flood elevations shall be used: Base Flood Elevation (BFE) = 2597.72 feet NAVD 1988 Regulatory Flood Elevation (RFE) =2598.72 feet NAVD 1988 All electrical components and junction boxes servicing the proposed additions are to be a minimum of 1' above the calculated BFE. 5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to electrical inspection or habitation. The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the structure as well as the identity and location of all other equipment/machinery servicing the structure. 6) Certification by an Arizona State Registered Professional Civil Engineer is required. 7) All work shall conform to the approved details and general site plan, which are made part of this permit. 8) No disturbance is permitted within the identified 100-year floodplain limits or the new identified protected riparian area. Any disturbance within either area will result in an automatic stop work order. 9) All equipment and personnel shall access site from the northern portion of parcel. 10) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T09OT01737 FOR INFORMATION PLEASE CALL 791-5550." 11) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 12) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 13) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after construction. 14) See the associated activity T09CM01709. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 12 Day: 16 Year: 2010 APPLICANT: Sunny Hennig ADDRESS: 1001 W Mission Twin Buttes, Green Valley, Arizona 85673 PHONE: (520) 343-4760 OWNER: David Yiu ADDRESS: 10238 E. Desert Flower Place, Tucson, AZ 85749 PHONE: SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 12/17/2009 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 12/17/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved |