10/20/2009 ANDREW CONNOR NPPO REVIEW Denied 1. Include limits of grading on the site plan.

2. Add the following notes to the site plan:

" Fencing shall be required during construction per DS 2-06.8.0 Fig.1 for all undisturbed natural desert areas of Protected Native Plants and for individual Protected Native Plants to be preserved-in-place. The area to be fenced shall be beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. For Saguaros and cacti, the area to be fenced shall be equal to the distance of one-half (½) the height of the plant per DS 2-15.6.0.

" NPPO PRE PERMIT INSPECTION MUST BE PERFORMED PRIOR TO GRUBBING OR GRADING.

3. Ensure that all Engineering comments and concerns are addressed prior to landscape approval
11/03/2009 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Approved
11/03/2009 TERRY STEVENS ZONING REVIEW Denied Zoning will approve the plan once engineering and landscape have approved the plan.
11/03/2009 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: November 3, 2009
SUBJECT: Addition of Garage and Porch
TO: Sunny Hennig
LOCATION: 10238 E Desert Flower Place, T13S, R15E, Section 35, Ward 2
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T09CM01709

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan and drainage statement for the above referenced property. Engineering Division does not recommend approval of the site plan or the drainage statement at this time. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments along with the corrected copies of the site plan and drainage statement.

Site Plan:

1. Complied
2. Complied
3. Correctly show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15.
Additional note: Identify the floodplain limits from the final plat and verify that location of existing residence has been correctly idenfitied on site.
4. Indicate cut & fill quantities on the site plan per D.S. 2-02.2.1.17
5. Indicate proposed finished floor elevation(s), and finished grades. DS Sec.2.02.2.1.A.16:
6. Complied
7. Provide legend and indicate all symbols on plans in legend.
8. Provide floodplain limits and erosion hazard setback limits on site plan per final plat. Provide floodplain limits per drainage report. Floodplain limits do not appear to be depicted correctly.
9. Draw the Final Plat lot boundaries with dimensions for all lines per the final plat and actual location of residence.
10. Per Floodplain Ordinance, Tucson Code Sec. 26-5.2.(4) Development in the floodway fringe shall not unnecessarily alter riparian habitats of watercourse and adjacent bank areas. Provide seal on the plan for engineering information regarding the location of the (floodplain limits).
11. Additional comments may be forthcoming.

Drainage Statement:

1. Scour protection must be tied into the existing erosion hazards setback structure (line) on both the upstream and downstream side of proposed development.
2. Complied
3. Complied
4. Acknowledged
5. Drainage report cannot be approved until ERR review has been completed.
6. Additional comments may be forthcoming.


Seal is required on the plan for engineering information (floodplain limits).


If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax

Final Status

Task End Date Reviewer's Name Type of Review Description
11/09/2009 DELMA ROBEY OUT TO CUSTOMER Completed
11/09/2009 SUE REEVES REJECT SHELF Completed