Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T09CM01641
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/16/2009 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1. A 5' continuous screen along entire street frontages for vehicle use area(s) must be provided per LUC Table 3.7.2-I. Non-wood fences must have wooden slat or high quality vinyl inserts to provide opacity. A 5' wall is required to screen vehicle use area from adjacent residential zoned properties. Portions of the vehicle use area are still visible from Canada St. and Liberty Ave. Identify all screening elements on the landscape plan. 2. All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution. Including the area between the right-of-way line and sidewalk and the area between the sidewalk and the curb. Identify areas to receive dust control on the landscape plan. 3. Identify water harvesting areas on the landscape plan. 4. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. 5. Additional comments may apply |
| 10/19/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 10/23/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 10/26/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: October 27, 2009 SUBJECT: Duplex TO: Dora Hurtado LOCATION: 302 W Canada Street #1 and #2, T15S R113 Sec1, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09CM01641 (3rd Review) RESUBMITTAL REQUIRED: Building Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed building plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. The following items need to be addressed to the next submittal: Please include a response letter to the comments along with the corrected copies of the site plan. BUILDING PLAN: 1. Complied. 2. Complied. 3. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. Specifically add sight visibility triangle for Canada St along Liberty Ave. Response: SVT still missing for Canada along Liberty Ave. 4. Provide dimensions for parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. PAAL needs to meet minimum 24' width requirement throughout paved area. 5. Complied 6. Complied 7. Standard Note: Verify that all easement of record have been graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 8. Label all dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 9. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Add spot elevations to show drainage flowing into water harvesting areas. Provide openings to permit the entry of water into water harvesting area and identify on plan. In addition, provide additional spot elevations to show positive flow into water harvesting areas in order to maximize water harvesting. 10. Complied 11. Complied 12. Show refuse container location, size, and access thereto fully dimensioned if being used as method of refuse per D.S. 2-02.2.1.32 and D.S. 6-01.0. Provide letter from Environmental Services approving proposed curb side pick up. Response: Provide actual letter with next submittal and tab for easy reference. 13. Standard Note: A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 14. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. Verify that positive flow is provided to allow for maximum water harvesting. Response: Additional spot elevations that clealy indicate positive flow may suffice. Will be determined with next submittal. 15. Complied. 16. Complied 17. Complied 18. Complied 19. Complied. 20. Additional comments may be forthcoming. If you have any questions, I can be reached at 791-5550 x1193 or Bianca.Ramirez@tucsonaz.gov Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 |
| 11/09/2009 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/10/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 11/10/2009 | SUE REEVES | REJECT SHELF | Completed |