Permit Number: T09CM01618
Parcel: 133400020

Address:
555 N PANTANO RD

Review Status: Completed

Review Details: OTHER

Permit Number - T09CM01618
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2009 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
07/06/2009 GERRY KOZIOL WWM REVIEW Approved
07/06/2009 THAUSER1 ELECTRICAL-COMMERCIAL REVIEW Needs Review
07/06/2009 THAUSER1 ZONING HC SITE REVIEW Needs Review
07/06/2009 THAUSER1 BUILDING-COMMERCIAL REVIEW Needs Review
07/06/2009 THAUSER1 MECHANICAL-COMMERCIAL REVIEW Needs Review
07/10/2009 RICK MYERS PLUMBING-COMMERCIAL REVIEW Denied 1. Reference 904.1 2006 UPC: The aggregate cross-sectional area of venting to be equal to the largest required building sewer. While you show one four inch vent at the lower end of the plumbing system, that four inch vent is being supplied by two, two inch vents. Provide 12.56 square inches of venting from the building drain through the roof. 2. Reference 908.2 2006 UPC: Each wet vented section shall be a minimum of one pipe size larger than the required minimum waste pipe size of the upper fixture, or shall be one pipe size larger than the minimum pipe size for the sum of the fixture units served by such wet vented section. Reference table 7-3 2006 UPC: The minimum waste size for a urinal is two inch. 3. Include in the Plumbing General Notes how thw domestic water system is to be sterilized. Reference 609.8 2006 UPC: Disinfection of potable water system.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/14/2009 DELMA ROBEY OUT TO CUSTOMER Completed
07/14/2009 SUE REEVES REJECT SHELF Completed