Permit Number: T09CM01604
Parcel: 11108022E

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM01604
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/24/2009 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T09CM01604
3649 East Bermuda street
New Duplex (111-08-022E)


TRANSMITTAL: September 24, 2009


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


This site is located in the R-2 Zone (LUC Section 2.3.5.2.A.2). The Development Designator is "K" (LUC Section 3.2.3.1.C) and the Perimeter Yard Indicator is BB (LUC Section 3.2.6.4).

Provide a cross access agreement for both parcels 111-08-022D and 111-08022E for the Parking Area Access Land (PAAL) or driveway.

The DSMR has been provided (DSMR 09-25).
09/28/2009 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. According to DSMR Case # 09-25. The four-plex development must comply with requirements of a commercial site as it pertains to landscape.

2. Submit a landscape plan to verify the entire site meets minimum requirements

3. A 10' interior landscape border is required along site boundaries of the adjacent residential properties per LUC Table 3.7.2-I.

4. A 5' wall must be provided to screen adjacent residential zoned properties form vehicle use areas per LUC Table 3.7.2-I.

5. Within a vehicular use area, every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.

6. All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution LUC 3.7.2.7.

7. Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants.

8. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

9. All landscape areas will be depressed to accept water flow from roofs, PAAL, and parking areas. Show by detail or spot elevations how landscape areas will accommodate water harvesting.

10. Additional comments may apply.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/30/2009 CINDY AGUILAR OUT TO CUSTOMER Completed
09/30/2009 SUE REEVES REJECT SHELF Completed