Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T09CM01574
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/22/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 2-22-10 Activity: T09CM01574 2nd Review Address: 1934 W Spring St Applicant: Chris Lespron Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans including revisions, details and calculations in accordance with the rules of the State Board of Technical Registration. SECTIONS - DETAILS: 3. Clarify attic ventilation details (If the insulation is tight to the roof deck then the attic is conditioned space and venting would compromise the thermal envelope). 4. Specify the manufacturer of asphalt shingles consistent with unvented attic assembly (vented attics would not have the insulation tight to the roof deck). PLUMBING PLAN: 5. Provide pressure and temperature relief valve for the water heater terminating to the exterior facing no more than 6 above the floor (How will the relief line get across the hallway without extending upward?), P2803.6.1. MECHANICAL PLAN: 6. Show the condensate line and secondary for HVAC unit (Condensate disposal may not discharge into a plumbing vent; location of secondary must terminate in an obvious location), M1411.3. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/23/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |