Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09CM01525
Parcel: 125020470

Address:
2801 E 2ND ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T09CM01525
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/30/2009 GERRY KOZIOL WWM REVIEW Approved
07/13/2009 RBROWN1 BUILDING-RESIDENTIAL REVIEW Denied 1. Provide a note on the cover sheet that the governing codes are the 2006 IRC and the 2006 UPC
2. Show how 8% of natural is provided to the existing activity room as per section R303.1.
3. Identify all the ceiling heights on the modified floor plan as per section R305.1.
4. Provide a tub enclosure specification note referencing to
nonabsorbent wall surfaces and fiber cement backer board.
5. Note on the foundation plan what the top of foundation elevation is in relation to the elevation of the street gutter, as per section r403.1.7.3 it is to be extended 12" plus 2% for new construction.
6. Provide values for roof dead and live loads.
7. Provide a header schedule consistent with table 502.5(1) or specify size of steel lintels.
8. Specify on the elevationsm, the height above grade for finished floor, windows/doors, exterior walls, rooflines, porches and etc.
9. For the stucco finish, indicate the ICBO #, system name and vapor barrier as per section R703.6.
10. Show stucco weep screeds 4" above grade or 2" above paving as per section RR703.6.2.1.
11. Please provide a detail for blocking at floor joists ends and bearing walls.
12. Please provide a detail for ledgers to masonry and /or framing.
13. Please provide details for non bearing interior wall conditions, floor and rafer/joist connections and gaps.
14. Please specify wall and ceiling covering. Note ceilingh gypsum board to be 5/8" or 1/2" sag resistant when applied to ceilings framed @ 24" o.c., IRC table 207.3.5, footnote "d".
15. Provide a 1" clearance between ceiling insulation and roof sheathing, R806.3.
16. Specify ledger connections to masonry wall, 3 x ledger material required, figure 606.11(1).
17. Specify lateral support of masonry walls, R606.9.
18. Provide an electrical riser diagram with grounding method and bonding to metallic piping, E3303,
E3507.
19. Provide riser diagrams for sub-panels with feeder conductors, conduit sizes, and over-current
protection (with appropriate correction factors), E3605.5.
20. Provide a panel schedule: panel size, circuit numbers, ampacity, and wire sizes, E3304.11, E3606.2.
21. Lights installed over a shower or bathtub must be approved for use in wet area, E3903.8
22. Bedroom outlets shall be arc-fault protected (receptacles, lights, and smoke detectors), E3802.12.
23. Show the size and location of all cleanouts, UPC 707.4, Table 7-6.
24. Provide location of return air ducts and register sizes, M1602.
25. Show supply and return ducts with minimum R-8 insulation, R1103.2.1.
26. Provide a note requiring the insulation certificate shall be posted in the electrical distribution panel
before final inspection, N1101.8.
END OF REVIEW