Permit Number: T09CM01454
Parcel: 113091730

Address:
2502 N 1ST AV

Review Status: Completed

Review Details: SITE

Permit Number - T09CM01454
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/09/2009 MARTIN BROWN FIRE REVIEW Approved
06/09/2009 RONALD BROWN ZONING HC SITE REVIEW Denied 1. If an accessible route is to be provided to the First Avenue Right of Way, as per Zoning requirements (reference Zoning comments), then a marked crossing and required ramps and detectable warnings strips complying with Sections 406.12 and 406.14 are required at the Nothern end of the site to cross the PAAL.
2. Also, a concrete (reference Zoning comments) accessible route will be required to the First Avenue R.O.W. complying with Section 403.3.
3. All the ramps required for accessibility accross the three drive entrances to the property are in the Public Right of Way and are subject to COT DOT construction regulations and standard detail 207. Please delete the note 9 reference and provide a separate note referencing to that effect.
4. Please change note 9 to read "...per 2006 IBC Chapter 11 and ICC/ANSI 117.1, Sections 405 and 406."
5. The detail reference mark located at the accessible parking aisle should reference detail 4/A1.2 and not 2/-?
6. Please delete the sidewalk ramp shown at the South East corner of the building and retain the 6" high curb at this location.
7. Please provide sufficient detail and manufacturer submittals and specifications for the noted (Note 23) "Metal Grated Walk Surface to insure compliance review with ICC/ANSI 117.1, 2003 Edition.
8. Provide a "Van Accessible" sign detail for detail 3/A1.3.

END OF COMMENTS
06/12/2009 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: June 17, 2009
SUBJECT: Site Plan
TO: Repp Design & Construction
LOCATION: 2502 N 1st Ave, 13S 14E Section 31, Ward 3
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T09CM01454 (First Review)


RESUBMITTAL REQUIRED: Site Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments along with the corrected copies of the site plan with the next submittal.

Site Plan:


1. Verify that all necessary sight visibility triangles are correctly indicated on site plan per D.S. 2-02.2.1.10.
2. Within location map call out section township range along with the section corners. In addition, identify north direction by providing north arrow for location map.
3. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. DS Sec.2-02.2.1.A.14: Provide (label and dimension) the required onsite maneuvering area for the loading zone that is shown adjacent to the proposed building. Refer to AASHTO for the national standards for turning radii.
4. DS Sec.2.02.2.1.A.16: Provide roof drainage arrows and locations of all concentration points. Specifically show roof down spout locations proposed buildings at pedestrian circulation areas. A detail for the dimension of the proposed scuppers that are used for collecting onsite roof drainage at all pedestrian sidewalk is required; refer to City of Tucson details. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk.
5. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. It appears that cut and fill will not be occurring for the proposed patio. However, as part of the site submittal requirement estimated cut and fill quantities are required to be indicated on the plans so that it is clear to the inspector that no cut in fill is to be taking place. If not cut and fill is taking place indicate the quantity of zero (0) on the plan. Estimated cut and Fill: Cut = 0 and Fill = 0 will suffice.
6. Please show accurate dimensions of right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19.
7. DS Sec.2-02.2.1.A.18: Provide a note stating that the site plan is in conformance with the MS&R overlay zone criteria.
8. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for 1st Ave and Alturas Street.
9. Label Alturas street as a local street.
10. DS Sec.2-02.2.1.A.19: Dimension existing sidewalk and curb area on the site plan to verify that all improvements are located outside of the existing ROW.
11. Label existing and future right-of-way.
12. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. Provide docket and page for easements identified on site plan.
13. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Provide contour interval on plan.
14. Verify that all fences, walls, or vegetation for screening and sight visibility are indicated by type, material, height, location and spacing per D.S. 2-02.2.1.27.
15. Provide the site plan activity number in the lower right hand corner of each sheet per D.S. 2-02.2.1.29.
16. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
17. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
18. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
19. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
20. All symbols on plans need to be indicated in legend. Indicate all symbols in legend.
21. Correct numbering and align comments with appropriate key number.
22. Verify that all key numbers are associated with the appropriate key note.
23. Within key notes identify the appropriate Development Standard.
24. Trash enclosure cannot be accessed from right of way get approval from Environmental Services and the Department of Transportation.
25. Correct handicap sign to read $532 FINE.
26. Additional comments may be forthcoming.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
06/17/2009 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: T09CM01454
2502 N. 1st Ave.
Site Plan

TRANSMITTAL DATE: 06/16/09

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. DS 2-02.2.1.2 Provide the legal description for this site on the plan.

2. DS 2-02.2.1.4 Enlarge the print indicating the section corners for the location map. Provide the township, range and section which this project is located in.

3. DS 2-02.2.1.6 Provide dimensions of all structures on the footprint of the buildings on the site plan as well as indicate the height of existing and proposed structures on the footprint.

4. Keynotes on page A1.1 have a drafting error in regards to the numbering corresponding to the note call out. Revise.

5. DS 2-02.2.1.8 Provide a cross reference from the site plan to the parking space detail on page A1.3.

In the zoning code portion of sheet TS in the Total Parking Required section revise the 4580 SF / 250 = 22.8 to read 4580 SF / 200 = 22.9.

6. DS 2-02.2.1.7 Provide a dimension from the structure supporting the solar panels to the nearest edge of travel lane of Alturas St. (min. 21' or the height of structure)

In the zoning code portion of sheet TS under the MS&R street building setback portion the indicated alley is not a street and therefore the setbacks required are per the adjacent zoning under development designator "DD". Adjacent to R-1 zoning the required setback is 1 ½ times the wall height of the structure. Revise all notes.

7. DS 2-02.2.1.9 Keynote #31 indicates the wrong code section (DS 6.09) should read DS2-09.

Cross reference the detail for the bicycle parking on sheet A1.3 to the site plan.

8. DS 2-02.2.1.10 Provide the location of the future sight visibility triangles. See engineering comments.

9. DS 2-02.2.1.11 A backup spur per DS 3-012.2.D is required at the south edge of the vehicular use area near the proposed loading zone. (3' radius, 3' clear behind the spur and min. 24' width)

10. DS 2-02.2.1.12 A pedestrian circulation path is required to connect from the building to the sidewalk area located along 1st Ave. See DS 2-08.3.1(connection to all adjacent streets)

Provide a pedestrian circulation path to the trash enclosure. See DS 2-08.3.1.

The cross walk indicated leading towards the parallel parking space along the east property line is not required but could be revised to meet the above comment regarding the trash enclosure.

11. DS 2-02.2.1.20 Provide the recording docket and page information for the easement indicated by key note #22.

12. DS 2-02.2.1.13 Indicate the locations and types of proposed signs (wall, freestanding, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Also indicate if there are existing billboards on site. Billboards will be required to meet all LUC requirements as stated in LUC Sec. 3.5.4.26. If none exists please state so.

13. Keynote #30 indicates a mailbox being provided, could not locate on the site plan. Clarify.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\T09CM01454.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
06/22/2009 JOE LINVILLE LANDSCAPE REVIEW Denied 1) New development is required to provide on-site refuse storage, collection, and pickup areas with service access from within the tract or from an alley adjacent to the tract. A DSMR is required to modify this standard. DS 6-01.4.1.A

2) Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee, up to five (5) feet of the required ten (10) foot width be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets. Provide written verification of any approvals received from the City Engineer. LUC 3.7.2.4.A.3

3) Include the legal; description on the landscape plans per DS 2-07.2.1.B.

4) Fences or walls constructed in a single continuous line shall extend into a street landscape border no more than the actual width of the fence or wall. Where a fence or wall incorporates offsets or similar design features, a screen may extend a maximum of three (3) feet into the street landscape border. Revise the plans to comply with LUC 3.7.3.2.C.3.
07/01/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve per Section 710.1, UPC 2006, as amended by the City of Tucson.
2. Revise the site drawing to show the location and size of both the water meter and the reduced pressure backflow preventer assembly. Reference: Section 103.2.3, UPC 2006.
07/01/2009 JOE LINVILLE NPPO REVIEW Denied Provide documentation per DS 2-15. for the exception request.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/02/2009 THAUSER1 OUT TO CUSTOMER Completed