Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T09CM01425
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/30/2009 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T09CM01425 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. GENERAL NOTES: " Limit all code references to those recognized by the City of Tucson. Adopted codes are listed at the Development Services web site. Revise 2000 or 2003 entries on sheet #1 and 5. " Interior alterations require the installation of smoke alarms at existing bedrooms, R313.2.1. SITE PLAN: 1. Indicate the location of the gas meter, R106.1.1. 2. Show the gas pipe size between the meter to the building and point of connection for new lines. The supply pipe must be sized for the calculated load, 2006 UPC 1217. FOUNDATION PLANS: 1. Revise the footing detail (sheet #5) showing materials, depth into undisturbed soil and rebar size, R403.1.1. 2. Revise the footing detail (sheet #6) showing vertical rebar size and spacing, R403.1.1. 3. Show the minimum 12" footing depth below undisturbed soil and appropriate width for supporting load at the 6 x 6 interior posts (sheet #5), R403.1.4. FLOOR PLANS: 1. Show under-floor space ventilation. Openings shall be not less than 1 SF for each 150 SF of area, R408.2. Show the location of a minimum 18"X24" access to under floor space that exceeds 30SF, R408.4. ELEVATIONS: 1. Provide an attic space ventilation calculation and specify size and location of all vents needed to comply, R806.2. 2. Note and specify the roof tile roofing system: Roof covering weight of materials or the ICBO evaluation report number, R905. 3. Note and specify the truss roof slope (Section B), R901.1. SECTIONS - DETAILS: 1. Show floor joist framing within 18" of exposed ground as pressure treated, R319.1 item 1. Sheet #5 and 6. 2. Show floor joist framing connection hardware. Sheet #5 and 6. 3. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d. 4. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2. PLUMBING PLANS: 1. The City of Tucson has adopted the 2006 Uniform Plumbing Code and 2006 International Residential Code with state amendments (ARIZONA STATE PLUMBING CODE). The plans should reference one of these codes for Plumbing. . 2. Show the individual accessible water supply shut off at the accessory building entrance, UPC 605.3. 3. Provide vent piping through the roof so that the aggregate cross-sectional area shall not be less than that of the largest required building sewer (3"), UPC 904.1. 4. Provide a gas line isometric showing the point of connection and size the supply pipe for the connected demand. Include the BTU demand and length of line to each gas appliance sharing a supply line, size and length of each branch, and the total demand and total developed length from the meter to the most remote appliance on the system. UPC 1217.2, & Table 12-8. Existing gas pipes may require upgrading. MECHANICAL PLANS: 1. Show supply and return ducts with minimum R-8 insulation (includes vented attics) except when completely located inside the thermal envelope, R1103.2.1. Show R-4.2 insulation when ducts are located in an unconditioned space (chase) inside the thermal envelope, IECC 503.2.7 (City of Tucson Amended). 2. Provide return air duct and register sizes for both units, M1602. Minimum duct/register size: heat pump or air conditioner - 6 SQ IN / 1000 BTU, M1403.1 (1 ton cooling = 12,000 BTU). ELECTRICAL PLANS: 1. Specify recessed lighting with 3" separation from combustibles or IC listing, R808, and compliance with energy efficiency leakage, N1102.4.3. 2. Smoke alarms are required outside each separate sleeping area, R313.2. 3. Show if Panel 'A' & 'B' are proposed or existing. If new show the Panel feeder size and grounding electrode on the Riser Diagram for the sub-panel, E3507.3. 4. Show Bathroom receptacles on a separate 20 AMP circuit (dedicated) with outlets at no other locations, E3603.4. Revise the laundry room (ckt #A12) receptacle circuit number. 5. Show receptacle outlets at each kitchen counter space with no point along the wall line more than 24" from a receptacle outlet, E3801.4.1. Add receptacles. 6. Show a GFCI receptacle outlet on the same level within 25' of exterior HVAC equipment, E3801.11. 7. Show all receptacle outlets serving kitchen countertops with ground fault circuit interrupting protection, E3802.6. Circuit #B15 & 19. 8. Note that combination type arc-fault circuit interrupter shall protect bedroom outlets including receptacles, lights and smoke detectors, E3802.12. Circuit #A13 & 20. OUTDOOR LIGHTING CODE 1. Provide spec sheets for all full cut-off fixtures showing the lamp type, placement and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style), OLC 5.1.2. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show the simplified prescribed energy value for above grade floors as R=13, N1102.1. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/20/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 08/20/2009 | SUE REEVES | REJECT SHELF | Completed |