| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2009 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED TO CLARIFY LOCATION OF CONNECTION TO PUBLIC- NEED TO CONNECT TO PUPLIC SEWER FRONTING LOT |
| 06/04/2009 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 06/09/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | June 9, 2009 1726 N Baxter Building Plan: SFR (Denied) Unable to approve building plan at this time. Re-submit for approval once lot split process has been completed. Bianca Ramirez, CFM Engineering Associate 520-837-4928 |
| 06/15/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | Provide copy of lot split when approved (See S09-035). Please be certain that the setback is large enough for the proposed building height. |
| 06/30/2009 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 7-01-09 Activity: T09CM01424 Address: 1726 N. Baxter Dr. Applicant: Ron O'Brien Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. SITE PLAN: 2. Specify overhead or underground electrical service and designate the proposed location of the utility line. Overhead service for new construction requires an appeal to the Building Official, IBC amendment section 111.1.1. 3. Provide gas piping for structure or submit exemption documentation, Arizona Statute 30-809. INCLUSIVE HOME DESIGN: 4. Provide a complete set of notes on the plan to meet the Inclusive Home Design Ordinance 10463. FLOOR PLANS: 5. Specify safety glazing in hazardous locations, R308.4. (within 24" of doorways) 6. Doors between a garage and a residence shall be self-closing minimum 20-minute fire-rated, R309.1 as amended. STRUCTURAL PLANS: 7. Specify the width of the wall panels on either side of the garage door consistent with the portal frame criteria, R602.10.6.2. 8. Provide interior braced wall lines at intervals not exceeding 35' from exterior wall lines, R403.1.6, R602.10.1.1, R602.10.8. 9. Provide accurate references to cross-section drawings. ELEVATIONS: 10. Provide keynotes on elevation page for all keynote references. PLUMBING PLAN: 11. The Uniform Plumbing Code and the International Plumbing Code are not interchangeable. Only one code may be specified for a plumbing design. 12. Provide a complete plumbing plan to include water supply and distribution to the plumbing fixtures. 13. Notate on plan all of the water conservation requirements: Water closets = 1.6 gallons per flush, Sinks/ Showerheads = 3 gpm, UPC State Amend. 45-312. ELECTRICAL PLAN: 14. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. Appeal to the Building Official for use of the 1999 NEC. 15. Provide circuit references on electrical layout at a minimum 3/32" in text height. 16. Provide all switches, receptacles, and controls within 48 inches of the floor but not less than 15 inches above the floor (to include thermostat controls) for the Inclusive Home Design Ordinance, 1003.9. 17. Bedroom outlets shall be protected with combination-type arc-fault breakers (receptacles, lights, and smoke detectors), E3802.12. 18. Provide an accurate electrical load calculation, E3502.2. 19. Use Table E3605.1 (60 degree C column) for sizing the air conditioner conductors. OUTDOOR LIGHTING CODE 20. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. 21. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/07/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 07/07/2009 | SUE REEVES | REJECT SHELF | Completed |