Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T09CM01419
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/22/2009 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Needs Review | PLAN REVIEW COMMENTS T09CM01419 Rev 7-8-09 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2005 National Electrical Code and Arizona Revised Statutes. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. STRUCTURAL PLANS: 1. Provide complete roof framing information for determining load carrying capacity for the longest rafter span, R301.1. Show the rafter length for determining load carrying capacity for supporting the additional (2.4 PSF) dead load along with a code required roof dead load and 20 PSF live load. Show the roof rafter span between load bearing structures and any additional support members for determining code compliance. NOTES/SPECIFICATIONS 1. Provide the exact wording and location for the DC Power Source "Ioc, Voc, Vmax, Isc" marking required by NEC 690.53 on the Notes pages under the Line Diagram. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 07/28/2009 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 07/28/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | |
| 07/28/2009 | SSHIELD1 | NPPO | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/29/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |