Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T09CM01382
Parcel: 123172760

Address:
1327 E LEE ST

Review Status: Active

Review Details: RESUBMITTAL

Permit Number - T09CM01382
Review Name: RESUBMITTAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
10/16/2009 RONALD BROWN BUILDING-RESIDENTIAL REVIEW Denied GENERAL
1. Height of lettering must be a minimum of 3/32". All documents have lettering less than 3/32", please revise,.
2. Please provide building code reference to the 2006 IRC.
3. Provide consecutive sheet numbers on each construction drawing, R106.1.1.
SITE PLAN
4. Location of utility lines and meters from property line to building, R106.1.1.
5. Provide gas piping for structure or submit exemption documentation, Arizona Statute 30-809.
FLOOR PLANS
6. Identify ceiling heights in all areas. Note average height at sloped ceiling areas, R305.1.
7. Provide a note for termite treatment, R320 as amended.
8. Note grade away from foundations shall fall min 6" within the first 10’, R401.3.
9. Note soil bearing pressure used in the design of the footings, Table R401.4.1
10. Note top of foundation to be extended 12" plus 2% (of distance between front face and curb) above the
street gutter, R403.1.7.3.
FRAMING PLANS
11. Location and size of roof drains/scuppers, UPC chapter 11.
ELEVATIONS
12. Specify height above grade for finished floor, windows/doors, exterior walls, rooflines, porches, chimneys, etc.
13. Indicate all materials used; stucco, concrete block, glass block, roofing system, siding, veneer, etc.
14. Provide an attic space ventilation calculation and note the size and location of all attic vents needed to comply, R806.
15. Specify roof slope and roofing type, grade of materials, and method of installation, R905.
a. Built-up: min slope ¼” per foot, R905.9.1.
16. Left Elevations shows erroneous electrical meter.
DETAILS AND SECTIONS
17. Cross-reference all cross-sections to the floor plan and framing plans.
18. 6" separation of untreated posts or columns above finished grade and 1” above concrete, R319.1.4. and a 6" clearance above grade to untreated exterior wood siding, sheathing and exposed wall framing,
R319.1 (5).
19. Specify water-resistive barrier over wall framing, R703.6.3.
20. Stucco: Show weep screeds with a min. clearance 4" above grade or 2" above paved areas, R703.6.2.1.
21. Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d.
22. Eave vents require min. 1" clearance between ceiling insulation and roof sheathing, R806.3.
ELECTRICAL PLANS
23. Provide an electrical riser diagram with grounding method and bonding to metallic piping, E3303,
E3507. Show an underground service entrance on the Riser Diagram or complete the Underground
Electrical Service Wavier form
24. Provide riser diagrams for sub-panels with feeder conductors, conduit sizes, and over-current protection (with appropriate correction factors), E3605.5.
25. TEP requires a 2½" diameter service conduit, TEP SR-305.
26. Provide equipment rated for 22,000 AIC short circuit protection when the underground cable length is less than 45 feet, 2006 Electric Service Requirements TEP SR-510.
27. Provide electrical load calculations for determining the service panel size, E3502.2.
28. Provide feeder load calculations for sub-panels (40% demand factor may not be applied), E3604.3.
29. Provide a panel schedule: panel size, circuit numbers, ampacity, and wire sizes, E3304.11, E3606.2.
30. For single-family dwellings, the service shall not be rated less than 100 amperes, E3502.1.
31. Show the location of the panel with a 30”W x 36”D clear working space, E3305.2, E3501.6.2.
32. The electrical plans still show this unit as a tri-plex electrical operation. It has now been changed to a single family residence. Please redesign the electrical for a single family residence.
33. Indicate location of all mechanical equipment disconnect switches, E4001.5.
34. Bathrooms require a separate 20-amp circuit with receptacles within 3’ of the basin, E3801.6.
35. Convenience receptacles and light switches/fixtures shall be provided within 25’ of mechanical equipment, E3801.11, E3803.4.
36. Laundry rooms require at least one 20-amp circuit that shall serve no other outlets, E3603.3, 3801.8.
PLUMBING PLANS
37. Provide pressure and temperature relief valve terminating to the exterior facing down between 6 and
24 inches above grade, UPC 608.5.
38. Each dwelling unit requires an individual accessible water supply shut off, UPC 605.3.
39. Drainage piping serving fixtures which have flood level rim located below the elevation of the next upstream manhole cover of the public sewer, shall be protected from back-flow of sewage by a backwater valve, UPC 710.1.
40. Show the size and location of all cleanouts, UPC 707.4, Table 7-6.
41. Provide a gas line isometric and size the supply pipe for the connected demand. Include the length of line and BTU demand for each appliance, size of each branch, total demand, and total developed length from meter to the most remote appliance on the system, UPC 1217.0 Table 12-8.
MECHANICAL PLANS
42. Please provide mechanical plans.
43. Mechanical shall comply with 2006 IRC chapters 12 - 24.
44. Provide a heated air source to all habitable rooms capable of maintaining a room temperature of 70 degrees at a point three feet above the floor, R303.8, 310.11.
45. Designate the location, capacity and fuel type of the heating and air conditioning equipment. Designate the locations of each supply register, return air grill and all ductwork.
46. Provide an equipment specification list, M1302.1.
47. Show dryer vent size and location for venting to exterior (max 25’ w/bend reductions), M1502.2, M1502.6.
48. Show exhaust fans for bathroom and kitchen venting min 50 and 100 CFM rating respectively, R303.3, M1507.
49. Gas appliances shall comply with ARIZONA STATE PLUMBING CODE combustion air requirements or Chapter 17, 2006 IRC. Show compliance for all appliances. Confined spaces require a minimum of two 100 SQ. IN. openings, M1702.2.
50. Gas fired water heaters may not be located in a storage closet, M2005.2.
OUTDOOR LIGHTING CODE
51. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in
accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style).
ENERGY CONVERSATION CODE
52. Provide a note requiring the insulation certificate shall be posted in the electrical distribution panel before final inspection, N1101.8.

END OF INSPECTION

Final Status

Task End Date Reviewer's Name Type of Review Description
10/20/2009 SUE REEVES REJECT SHELF RECEIVED