Permit Number: T09CM01382
Parcel: 123172760

Address:
1327 E LEE ST

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T09CM01382
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2009 GERRY KOZIOL WWM REVIEW Approved
07/07/2009 MARTIN BROWN FIRE REVIEW Denied Should be classified R-4. Fire sprinklers required.
07/07/2009 RONALD BROWN ADA REVIEW Passed NOT A COT OWNED/OPERATED PROPERTY
07/16/2009 ROBERT SHERRY WATER REVIEW Passed
07/16/2009 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Provide plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304.
2. The 2006 International Mechanical Code with Local Amendments is the relevant code for this project.
07/16/2009 JOHN WILLIAMS COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed IMPACT FEES APPLY; CENTRAL DISTRICT, 1 UNIT 975 SQ FEET $4170.00
07/16/2009 ERIC NEWCOMB ZONING HC SITE REVIEW Denied 1. SEE BUILDING COMMENTS.
07/16/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. PROVIDE PLAN SEALED BY AN ARIZONA REGISTRANT. REFERENCE: ARIZONA REVISED STATUTES 32-125, BOARD OF TECHNICAL REGISTRATION RULES R4-30-304.
2. THE 2006 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS IS THE RELEVANT CODE FOR THIS PROJECT.
3. NO REVIEW WAS PERFORMED AT THIS TIME DUE TO COMMENTS 1 AND 2.
07/17/2009 RICK MYERS PLUMBING-COMMERCIAL REVIEW Denied 1. 2006 IRC is limited to one and two family dwellings. Three units to be installed per 2006 UPC. 2. These plans are to include the archetects seal. Reference 103.2.2 2006 UPC: ...plans, computations, and specifications to be prepared by, and the plumbing designed by, an engineer and/or archetect licensed by the state to practice as such. 3. Provide material types for all piping. 4. Show water meter size, and provide calculations for water piping, include all pipe sizing. 5. Include how the water system is to be sterilized. Reference 609.9 2006 UPC: Disinfection of water system. 6. At stacked water heaters: a. Provide a detail showing water heater stand, and include how it is to be supported. b. Show the water heater pan and drain. Reference 508.4 2006 UPC: ...where damage may result from a leaking water heater, a water tight pan shall be installed beneath the water heater, with a minimum 3/4" drain to an approved location. c. Install a vacuum relief valve as necessary. Reference 608.7 2006 UPC: Where a hot water storage tank or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater. 7. Include hammer arrestors at the washer connection. Reference 609.10 2006 UPC: All building water supply systems in which quick-acting valves are installed shall be provided with devices to absorb the hammer... 8. Show valves at each unit. Reference 605.3 2006 UPC: In multidwelling units, one or more shut off valves shall be provided in each dwelling unit so that the water supply to any plumbing fixture or group of fixtures in that dwelling unit can be shut off without stopping water supply to fixtures in other dwelling units.
07/17/2009 ROBERT SHERRY ELECTRICAL-COMMERCIAL REVIEW Denied 1. Provide plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304.
2. The 2005 National Electrical Code with Local Amendments is the relevant code for this project.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/22/2009 CPIERCE1 OUT TO CUSTOMER Completed
07/22/2009 SUE REEVES REJECT SHELF Completed