Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T09CM01382
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/06/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 07/07/2009 | MARTIN BROWN | FIRE | REVIEW | Denied | Should be classified R-4. Fire sprinklers required. |
| 07/07/2009 | RONALD BROWN | ADA | REVIEW | Passed | NOT A COT OWNED/OPERATED PROPERTY |
| 07/16/2009 | ROBERT SHERRY | WATER | REVIEW | Passed | |
| 07/16/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. The 2006 International Mechanical Code with Local Amendments is the relevant code for this project. |
| 07/16/2009 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | IMPACT FEES APPLY; CENTRAL DISTRICT, 1 UNIT 975 SQ FEET $4170.00 |
| 07/16/2009 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
| 07/16/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PROVIDE PLAN SEALED BY AN ARIZONA REGISTRANT. REFERENCE: ARIZONA REVISED STATUTES 32-125, BOARD OF TECHNICAL REGISTRATION RULES R4-30-304. 2. THE 2006 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS IS THE RELEVANT CODE FOR THIS PROJECT. 3. NO REVIEW WAS PERFORMED AT THIS TIME DUE TO COMMENTS 1 AND 2. |
| 07/17/2009 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. 2006 IRC is limited to one and two family dwellings. Three units to be installed per 2006 UPC. 2. These plans are to include the archetects seal. Reference 103.2.2 2006 UPC: ...plans, computations, and specifications to be prepared by, and the plumbing designed by, an engineer and/or archetect licensed by the state to practice as such. 3. Provide material types for all piping. 4. Show water meter size, and provide calculations for water piping, include all pipe sizing. 5. Include how the water system is to be sterilized. Reference 609.9 2006 UPC: Disinfection of water system. 6. At stacked water heaters: a. Provide a detail showing water heater stand, and include how it is to be supported. b. Show the water heater pan and drain. Reference 508.4 2006 UPC: ...where damage may result from a leaking water heater, a water tight pan shall be installed beneath the water heater, with a minimum 3/4" drain to an approved location. c. Install a vacuum relief valve as necessary. Reference 608.7 2006 UPC: Where a hot water storage tank or an indirect water heater is located at an elevation above the fixture outlets in the hot water system, a vacuum relief valve shall be installed on the storage tank or heater. 7. Include hammer arrestors at the washer connection. Reference 609.10 2006 UPC: All building water supply systems in which quick-acting valves are installed shall be provided with devices to absorb the hammer... 8. Show valves at each unit. Reference 605.3 2006 UPC: In multidwelling units, one or more shut off valves shall be provided in each dwelling unit so that the water supply to any plumbing fixture or group of fixtures in that dwelling unit can be shut off without stopping water supply to fixtures in other dwelling units. |
| 07/17/2009 | ROBERT SHERRY | ELECTRICAL-COMMERCIAL | REVIEW | Denied | 1. Provide plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. The 2005 National Electrical Code with Local Amendments is the relevant code for this project. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/22/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 07/22/2009 | SUE REEVES | REJECT SHELF | Completed |