Permit Number: T09CM01379
Parcel: 11901076A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM01379
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/08/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
09/09/2009 ERIC NEWCOMB ZONING HC REVIEW Approved
09/18/2009 GERRY KOZIOL WWM REVIEW Denied need wastewater 5th floor credit evaluation for removal of 1 toilet & 1 lav per demo drawings
09/18/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
09/18/2009 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Comment not resolved; it is the owner's responsibility to maintain the approved drawings. Provide a copy of the approved drawings for the shell package of the building to establish the existing conditions of the tenant space. Reference: Sections 106.1 and 106.3, IBC 2006.
Comment not resolved. The information shown on sheet MP-1 indicates that the building does not meet the prescriptive energy code requirements of IECC 2006 due to the SHGC for the windows; the wall are called out as having R-19 insulation but the architectural drawing do not indicate any insulation in the walls; and key note #4 on sheet A2 is ambiguous with regard to the location of the R-30 insulation (see Section 502.2.1, IECC 2006). Provide energy code compliance calculations (climate zone for Pima County < 4,000 feet). Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope and the mechanical system. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006.
09/22/2009 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Denied SEE COMMENTS FOR T09CM01377

Final Status

Task End Date Reviewer's Name Type of Review Description
10/27/2009 DELMA ROBEY OUT TO CUSTOMER Completed