Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T09CM01207
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: May 15, 2009 SUBJECT: Ramada TO: Silvia Villa LOCATION: 849 N Anita Ave, T14S, R13E, Section 11, Ward 1 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09CM01207 (First Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the SP. Site Plan: 1. The most recent aerial photo of the building does not match what is depicted on the site plan. Please modify site plan to represent actual footprint of building and/or clarify. Specifically, explain structure located in northeast corner of parcel per 2008 aerial photo. 2. Please revise the project location map so that it is approximately one (1) square mile, drawn at a minimum of 3' = 1mile. 3. Please label lot bearings per D.S. 2-02.2.1.5 4. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. Provide scope of work to be done on site plan so that is clear as to what already exists and what is proposed, label within plan accordingly. 5. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 6. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 7. Fully dimensioned loading space(s) and/refuse vehicle access areas along with maneuvering area(s) per D.S. 2-02.2.1.14. 8. DS Sec.2-02.2.1.A.14: Provide (label and dimension) the required onsite maneuvering area for the refuse container that is shown on the site plan. The maneuvering area has to be provided onsite for the refuse area. If onsite maneuverability can not be achieved then a variance must be submitted and approved for offsite maneuvering within the public right-of-way. The site plan can not be approved until such variance is approved. Refer to AASHTO for the national standards for turning radii. 9. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 10. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. D.S. Sec.2-02.2.1.17: It appears that cut and fill will not be occurring for the proposed ramada. However, as part of the site submittal requirement estimated cut and fill quantities are required to be indicated on the plans so that it is clear to the inspector that no cut in fill is to be taking place. If not cut and fill is taking place indicate the quantity of zero (0) on the plan. Estimated cut and Fill: Cut = 0 and Fill = 0 will suffice. 11. Label all roads accordingly as to whether they are public or private. Also call out roads as Local Streets. 12. Label Lord Street and Anita Avenue as Local Streets. 13. Label and indicate future right-of-way. If existing and future right of way are the same, label existing/future right of way. 14. Verify that all easement of record have been graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 15. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 16. Identify location and orientation of existing major physical features, such as railroad tracks and drainageways per D.S. 2-02.2.1.22. 17. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Provide contour interval on plan. 18. Verify that all fences, walls, or vegetation for screening and sight visibility have been depicted and labeled by type, material, height, location and spacing per D.S. 2-02.2.1.27. 19. Show Site Plan activity number in the lower right hand corner of plan per D.S. 2-02.2.1.29. 20. Provide detail for refuse container fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. See enclosed detail. 21. DS Sec.2-02.2.1.A.32: Label and show the maneuverability for refuse vehicles in plan view at the proposed refuse container location. Current positioning of trash area does not allow for 14' X 40' clear approach, show access dimensioning to proposed trash enclosure without backing up into right of way. Provide 14' dimension. 22. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 23. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. 24. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. 25. Add note: "Depress all landscaped areas 6" maximum for water harvesting". 26. All symbols on plans need to be indicated in legend. Indicate all symbols on plans and reference in legend. Also reference all details and site information for easy reference. 27. A floodplain use permit is required. See enclosed Floodplain Use Permit. 28. Provide floodplain information on site plan include Panel Number, Community Number, Special Flood Hazard Area Zone, etc. 29. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. 30. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/30/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 07/30/2009 | SUE REEVES | REJECT SHELF | Completed |