Review Details: SITE
Permit Number - T09CM01201
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2009 | DAVE MANN | FIRE | REVIEW | Approved | |
| 05/14/2009 | RBROWN1 | ADA | REVIEW | Denied | 1. Of the four accessible parking spaces provided, one space needs to be "Van Accessible". Show on both the site plan and large scale details. 2. The accessible path in front of the parking may be required by Zoing to be concrete. Reference Zoning comments and revise as directed. 3. Show accessible parking signs on the site plan. 4. Page 6 of XX: Change the second note 26 to 27 and revise the number reference for the ramps at the accessible parking. 5. Page 7 of XX: Provide the required quantity of accessible seating at both bleacher seating areas as per ADAAG, Sections 4.1.3 (19) and 4.33. END OF REVIEW |
| 05/18/2009 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Purple Heart Park - New Ball Field T09CM01201 Site Plan (1st Review) TRANSMITTAL DATE: May 18, 2009 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the area of expansion. 2. Not used. 3. D.S. 2-02.2.1.A.2 Provide a property description, legal description, on the plan. 4. D.S. 2-02.2.1.A.5 Show all parcel lines on the plan along with dimensions and bearings. 5. D.S. 2-02.2.1.A.8 Show all existing parking for the entire site on the site plan. 6. D.S. 2-02.2.1.A.9 Provide a bicycle parking detail that includes materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage. Layout and Construction Note 26 calls out "Bollard Post Bike Racks". Based on the description "Bollard" this proposed bike rack may not meet the requirements of Revised D.S. 2-09.0, please review the revised standard. 7. D.S. 2-02.2.1.A.10 Show the sight visibility triangles (SVTs) for the new entrance/exit parking area access lanes (PAALs) on the plan. 8. D.S. 2-02.2.1.A.12 The proposed "Asphalt Path" called our along the east side of the proposed parking area is required to be a sidewalk that meets the requirements of D.S. 2-08.5.1.C. 9. D.S. 2-02.2.1.A.18 On sheet 2 label Rita Road as an MS&R route. 10. D.S. 2-02.2.1.A.19 Provide right-of-way (ROW) dimensions for all ROWs adjacent to this site. 11. D.S. 2-02.2.1.A.20 If applicable show all easements of record graphically on the plan along with the recordation information, docket and page. 12. D.S. 2-02.2.A.1 Under "DEVELOPMENT REGULATIONS, Minimum Requirements", Page 2, the total site area is listed as 7,404,220.0 S.F.. Under "SITE INFORMATION, Total Site Area", Page 2, the total site area is listed as 40 acres or 1,742,400.0 S.F., please clarify which number is correct. 13. D.S. 2-02.2.A.4 Provide a vehicle and bicycle parking calculation that includes all required and provided parking for the entire park, i.e. pool, skate park etc. 14. Depending on how the above comments are addressed addition comments may be forth coming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t09cm01201 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents. |
| 05/21/2009 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | |
| 05/21/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approv-Cond | |
| 05/22/2009 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 06/08/2009 | LOREN MAKUS | ENGINEERING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/01/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |