Permit Number: T09CM01041
Parcel: 105095510

Address:
4701 N STONE AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM01041
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2009 RONALD BROWN ZONING HC REVIEW Denied Reference Building Folder for comments
09/18/2009 RICK MYERS PLUMBING-COMMERCIAL REVIEW Denied 1. At the snack bar three compartment sink, only one compartment may be indirectly wasted if it is a vegetable prep bowl, or a sanitizing bowl. The other two bowls are to be directly connected, like the other three compartment sinks. 2. Response to question asking for floor slope at floor drains, says to refer to the enlarged architectural drawings. Enlarged restroom plans on sheet A-5 do not show the floor drains nor how to slope the floor to them.
09/18/2009 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied 1. As per Development Services Department standards, all lettering is to be a minimum of 3/32", all capitals. Please correct the following drawings as requested on previous review: CS, CA2, CA3, and CA4.
2. As per previous review comments, Door 152A requires an 18" clearance at strike jamb.
3. Also previously commented, there is a conflict in details 2AG1.1 and 3/M3.1. Please provide a wall section detail clarifying the exhaust requirements of the back of the hood and how and where the stainless steel finish is located and is supported.
4. The revision sheets are a submittal package not included with the full set of documents. A full set of drawings including revised sheets is required for approval stamp.

END OF REVIEW.
09/18/2009 STEVE SHIELDS ZONING REVIEW Approv-Cond DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: SAM's Club Remodel
T09CM01041
Site & Building Plan

TRANSMITTAL DATE: September 18, 2009

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

The Zoning Review Section conditionally approves the site and building plan for this project, subject to the following:
Zoning will stamp and approve the plans once the revised sheets are inserted into to main set of plans and all other reviews are completed and approved.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t09cm01041

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
09/28/2009 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
09/29/2009 BIANCA RAMIREZ ENGINEERING REVIEW Approved .

Final Status

Task End Date Reviewer's Name Type of Review Description
11/23/2009 CINDY AGUILAR OUT TO CUSTOMER Completed
11/23/2009 SUE REEVES REJECT SHELF Completed