Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T09CM01020
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/07/2009 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 7-07-09 Activity: T09CM01020 Address: 4539 E. Water St. Applicant: Smith Construction Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FLOOR PLANS: 2. Specify safety glazing in hazardous locations, R308.4. (within 24" of doorways) FOUNDATION PLANS: 3. All exterior framed walls require continuous concrete footings min. 12"wide x 12" below grade with treated sill plates and anchor bolts per R319.1 & R403.1.6 (including carport and porch enclosures). 4. Provide sufficient footings for braced wall panels, R401.2. STRUCTURAL PLANS: 5. Justify the ability of the existing 4x8 beam in the carport area to support the proposed additional 5 feet of tributary roof area and an additional 5psf for insulation and ceiling finishes, R801.2. 6. Detail non-bearing wall connection to existing pre-engineered truss. 7. Provide an attic space ventilation calculation and note the size and location of all attic vents needed to comply, R806.2. PLUMBING PLAN: 8. Provide a gas line layout if the existing gas line is to be relocated. Any underground gas piping beneath buildings shall be encased in an approved sealed & vented conduit, UPC 1211.1.6. OUTDOOR LIGHTING CODE 9. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/08/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 07/08/2009 | CPIERCE1 | REJECT SHELF | Completed |