Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T09CM00965
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2009 | DAVE MANN | FIRE | REVIEW | Needs Review | |
| 04/24/2009 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 04/28/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET AB1 OF 4; GENERAL NOTES (1): ADD ..."AS INDICATED ON SHEETS AB2, AB3, AND AB4"... 2. SEE BUILDING COMMENTS FOR PROJECT T09CM00963. |
| 04/29/2009 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Passed | |
| 05/05/2009 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: May 5, 2009 REVIEWERS: Jason Green, CFM ACTIVITY: T09CM00965 (Building Plan) SUMMARY: Engineering Division of Development Services Department has received the building plan (T09CM00965). Engineering Division does not recommend approval of the building plan application at this time. The following items need to be addressed: BUILDING PLAN COMMENTS: 1) Engineering could not verify that the building plan was in compliance with the stamped approved Development Plan (D09-0009). Please submit two copies of the stamped approved Development Plan, landscape, and NPPO plans with the next building plan submittal. 2) Engineering will re-review the building plan on the next submittal to insure compliance with the approved and stamped Development Plan. Additional comments may be forthcoming. GENERAL COMMENTS: Please provide the building plan with a copy of the last approved Development Plan (D09-0009). Further comments may be generated upon resubmittal of the building plan review. For questions or to schedule an appointment I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 05/05/2009 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | See comments for T09CM00963, these items required to be corrected since plans are same for Canopy and Dispensers as for Convenience Store. Ray T Majuta Electrical Plan Ck 5-08-09 |
| 05/13/2009 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Quick Trip #1493 T09CM00963, T09CM00965 & T09BU00600 Building Plan (1st Review) TRANSMITTAL DATE: May 13, 2009 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the building plan was in compliance with the approved development plan. Please submit two copies of the approved and stamped development plan with the next building plan submittal. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped development plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\grading\t09cm00963.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |
| 05/21/2009 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 05/21/2009 | ROBERT SHERRY | WATER | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/25/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 09/25/2009 | SUE REEVES | REJECT SHELF | Completed |