Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T09CM00831
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 09/02/2009 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 09/24/2009 | RONALD BROWN | BUILDING-RESIDENTIAL | REVIEW | Denied | 25 September 2009 FLOOR PLANS 1. Tub/shower enclosures require fiber-cement board backing, R307.2, R702.4.2. FOUNDATION PLANS 2. Provide a note for termite treatment, R320 as amended. STRUCTURAL FRAMING PLANS 3. Specify design criteria on plans. Provide values for floor/roof dead and live loads. ELEVATIONS 4. For thin-coat stucco systems, indicate the ICBO #, system name, and vapor barrier, R703.6. 5. Reference Detail 5/A-2, Note 16 where it referes to the new stucco applied to the existing wood siding as "Existing Stucco". SECTIONS/DETAILS 6. Stucco: Show weep screeds with a min. clearanceb 4" above grade or 2" above paved areas, R703.6.2.1. 7. Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. ELECTRICAL PLANS 8. Show locations of smoke detectors (every sleeping room and hallways leading to). All smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke detectors, R313. Smoke detectors are required in existing buildings when interior alterations occur, R313.2.1. 9. Bathrooms require a separate 20-amp circuit with receptacles within 3’ of the basin, E3801.6. 10. Exterior outlets at grade level shall be provided at both the front and back of the dwelling, E3801.7. These outlets shall be GFCI protected E3802.3. 11. Please provide an outlet for the gas dryer. PLUMBING PLANS 12. Provide a gas line isometric and size the supply pipe for the connected demand. Include the length of line and BTU demand for each appliance, size of each branch, total demand, and total developed length from meter to the most remote appliance on the system, UPC 1217.0 Table 12-8. INTERNATIONAL ENERGY CONSERVATION CODE 13. Provide a note requiring the insulation certificate shall be posted in the electrical distribution panel before final inspection, N1101.8. END OF REVIEW |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/07/2009 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 10/07/2009 | SUE REEVES | REJECT SHELF | Completed |