Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T09CM00797
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/03/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
08/03/2009 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
08/04/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
08/06/2009 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Comment not addressed. Show that the floor of the restroom slopes toward the floor drain. Reference 411.4 2006 UPC: Floors shall be sloped to the floor drains. 2. The flow control device for the hydromechanical grease interceptor not installed per code. Reference 1014.2.1 2006 UPC: Each plumbing fixture or piece of equipment connected to a hydromecanical grease interceptor shall be provided with an approved type of vented flow control installed in a readily accessible and visible location. |
08/11/2009 | TERRY STEVENS | ZONING | REVIEW | Approved |