Permit Number: T09CM00671
Parcel: 10601228D

Address:
3657 N 1ST AV

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T09CM00671
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/31/2009 JOHN WILLIAMS COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed Impact Fee's Do Apply; Central District; 3,800 Square Foot Warehouse; $11,138.40
04/01/2009 TERRY STEVENS ZONING REVIEW Denied 04/02/2009

Development Services Department
Zoning Review Section

Terry Stevens
Lead Planner

Comments:

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the building plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next building plan submittal.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved site plan. Additional comments may be forthcoming.
04/01/2009 MARTIN BROWN FIRE REVIEW Denied Too far from existing hydrant. Fire sprinklers or additional hydrant required. Also, please provide fire department approved lock box at rolling gate.
04/03/2009 GERRY KOZIOL WWM REVIEW Passed
04/07/2009 RONALD BROWN ZONING HC SITE REVIEW Passed
04/08/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved 1. A MINIMUM OF 3/32" LETTERING IS REQUIRED ON ALL DRAWINGS UNLESS A WRITTEN APPEAL IS APPROVED BY THE BUILDING OFFICIAL, JESSIE SANDERS. THIS APPROVED APPEAL MUST ACCOMPANY DRAWINGS SUBMITTED FOR CHECKING.
2. SHEET 2; ROOF FRAMING PLAN: REVISE THE PLAN TO SHOW THE ENTIRE BUILDING LAYOUT. THE 40' WIDTH AS SHOWN DOES NOT WORK WITH THE BAY WIDTHS INDICATED.
3. SHEET 2; ROOF FRAMING PLAN: REVISE THE PLAN TO INDICATE A BOXED COLUMN AT THE CENTER OF THE SPANS.
4. SHEET 3 (DETAIL 7); CALCULATIONS (PAGES 13, 16, AND 19): THE CALCULATIONS INDICATE 2- 3/4" DIAMETER ANCHOR BOLTS REQUIRED AT ALL COLUMNS. DETAIL 7 INDICATES 2 OR 4- 1/2" A307 BOLTS. CLARIFY AND REVISE.
5. SHEET 3 (DETAIL 9); CALCULATIONS (PAGE 28): THE CALCULATIONS INDICATE 2-10X3.5X14 GA. BOX COLUMN WHILE DETAIL 9 (NOTE 5) INDICATES TWO 8"X3 1/2"X14 GA. 'C' COLUMN (BOXED). CLARIFY AND REVISE.
6. SHEET 3 (DETAIL 6): SIDE VIEW REFERENCES KEY NOTE 25. REVISE TO NOTE 21? VERIFY.
7. SHEET 3 (DETAIL 7): TOP VIEW REFERENCES KEY NOTE 25. REVISE TO NOTE 21? VERIFY.
8. SHEET 3 (DETAIL 12): WHERE IS THIS DETAIL REFERENCED? KEY NOTES 11, 14, 15, AND 21 SHOULD BE VERIFIED.
9. SHEET 3 (DETAIL 13): KEY NOTES 11 AND 21 SHOULD BE VERIFIED.
04/20/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
04/20/2009 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
04/20/2009 ROBERT SHERRY WATER REVIEW Passed
04/20/2009 JASON GREEN ENGINEERING REVIEW Denied DATE: April 22, 2009
SUBJECT: 3657 N 1st Avenue Building Plan- Engineering Review
TO: Steve Koch
LOCATION: T14S R14E Sec18 Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: T09CM00671 (Building Plan)


SUMMARY: Engineering Division of Development Services Department has received the building plan (T09CM00671). Engineering Division does not recommend approval of the building plan application at this time. The following items need to be addressed:


BUILDING PLAN COMMENTS:

1) Engineering could not verify that the building plan was in compliance with the stamped approved Site Plan (T09CM00671). Please submit two copies of the stamped approved Site Plan, landscape, and NPPO plans with the next building plan submittal.

2) Engineering will re-review the building plan on the next submittal to insure compliance with the approved and stamped Site Plan. Additional comments may be forthcoming.


GENERAL COMMENTS:

Please provide the building plan with a copy of the last approved Site Plan (T09CM00671). Further comments may be generated upon resubmittal of the building plan review.

For questions or to schedule an appointment I can be reached at 837-4929.




Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Development Services
04/23/2009 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
05/06/2009 THAUSER1 OUT TO CUSTOMER Completed
05/06/2009 SUE REEVES REJECT SHELF Completed