Permit Number: T09CM00585
Parcel: 13613036A

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T09CM00585
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2009 GERRY KOZIOL WWM REVIEW Denied need to show location/method to public sewer
03/17/2009 ANDREW CONNOR NPPO REVIEW Approv-Cond
03/18/2009 MARTIN BROWN FIRE REVIEW Denied Need smoke detectors in bedrooms 1 and 2. Reference 2006 IFC 907.2.10.1.2
(bedrooms mislabeled on sheet 12)
No sprinkler requirement due to proximity of a fire hydrant with sufficient fire flow.
04/08/2009 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 4-09-09
Activity: T09CM00585
Address: 9335 E. Sellarole Rd
Applicant: Al Leon

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

INCLUSIVE HOME DESIGN:
2. Specify the intended accessible route. Note: Vertical changes in floor elevation may not exceed ¼ inch (½ inch when beveled), 1003.4.

FLOOR PLANS:
3. Specify safety glazing in hazardous locations, R308.4. Within 18" of the floor when individual panes exceed 9 square feet, within 24" of doorways, and less than 60" above tub/shower floors.

ELEVATIONS:
4. Specify two-layer underlayment for low-slope shingle roofs (2:12 to 4:12), R905.2.7.
5. For thin-coat stucco systems, indicate the ICC ESR #, system name, and vapor barrier, R703.6.

SECTIONS - DETAILS:
6. Specify stucco weep screeds with a min. clearance 4" above grade or 2" above paved areas, R703.6.2.1.
7. Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d.

PLUMBING PLAN:
8. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, UPC 609.10.
9. All SFR and Duplex plans submitted after March 1, 2009 require a solar water system, or future installation preparation with one of the following provisions: control and ¾"water piping; 3" metallic sleeve; or an accessible attic over the water heater.

MECHANICAL PLAN:
10. Show supply and return air ducts with a minimum R-8 insulation, R1103.2.1.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review
04/17/2009 MICHAEL ST. PAUL ZONING REVIEW Approv-Cond CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician
FOR: David Rivera Principal Planner


PROJECT:
T09CM00585
9335 South Sellarole Road
New SFR


TRANSMITTAL: April 17, 2009


COMMENTS: The following conditions apply to this approval.


This conditional approval is for a single-family residence (SFR) in the SR Zone (LUC Section 2.2.4.2.A). The Development Designator is "C" (LUC 3.2.3.1.A) and the Perimeter Yard Indicator is BB (LUC Section 3.2.6.4).

The maximum number of residential units in the SR zone is one (1) per lot (LUC Section 3.2.3.1.A).

All kitchens must be removed from the existing unit or units prior to allowing occupation of the new SFR and issuing a certificate of occupation (C of O).

All structures must be inspected for zoning compliance before a C of O can be issued.

The existing unit which is to be converted to detached living quarters or a storage facility must be less than or equal to forty-nine percent (49%) of the proposed single-family residence.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/21/2009 CPIERCE1 OUT TO CUSTOMER Completed
04/21/2009 SUE REEVES REJECT SHELF Completed